Introduction
This manual provides technical information necessary for servicing the VXR-7000 FM Land Mobile Repeater.
Servicing this equipment requires expertise in handling surface-mount chip components. Attempts by non-qualified
persons to service this equipment may result in permanent damage not covered by the warranty, and may be illegal in
some countries.
Two PCB layout diagrams are provided for each double-sided circuit board in the repeater. Each side of is referred to
by the type of the majority of components installed on that side (“leaded” or “chip-only”). In most cases one side has only
chip components, and the other has either a mixture of both chip and leaded components (trimmers, coils, electrolytic
capacitors, ICs, etc.), or leaded components only.
While we believe the technical information in this manual to be correct, VERTEX STANDARD assumes no liability
for damage that may occur as a result of typographical or other errors that may be present. Your cooperation in pointing
out any inconsistencies in the technical information would be appreciated.
©2006 VERTEX STANDARD CO., LTD. (E136890B)
Service Manual
VXR-7000 (UHF)
Desktop Repeater
Operating Manual Reprint............................ 2
CE27 Programming Software Instruction ...........................
10
Specifications ................................................. 16
Exploded View & Miscellaneous Parts .... 17
Block Diagram ............................................... 21
Interconnection Diagram............................. 24
Circuit Description ...................................... 25
Alignment ....................................................... 28
Board Unit (Schematics, Layouts & Parts)
PA Unit (Lot.1-17, 18, 19-61) ..................................... 33
PA-2 Unit (Lot.62-) ..................................................... 41
Contents
TX Unit (Lot.1-59) ................................................... 49
TX-2 Unit (Lot.60-) ................................................. 57
RX Unit (Lot.1-59)................................................... 65
RX-2 Unit (Lot.60-) ................................................. 75
CNTL Unit ............................................................... 85
Display Unit .......................................................... 103
Key Unit ................................................................. 107
Filter Unit (50W Type) ......................................... 113
Filter-2 Unit (25W Type) ..................................... 119
SW Unit (25W Type) ............................................ 125
VR Unit .................................................................. 127
SQL Unit ................................................................ 128
PS Unit ................................................................... 129
VERTEX STANDARD CO., LTD.
4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan
VERTEX STANDARD
US Headquarters
10900 Walker Street, Cypress, CA 90630, U.S.A.
YAESU EUROPE B.V.
P.O. Box 75525, 1118 ZN Schiphol, The Netherlands
YAESU UK LTD.
Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
VERTEX STANDARD HK LTD.
Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road,
Kwun Tong, Kowloon, Hong Kong