Bloomfield ELECTRONIC BREW CONTROL 1090 User Manual

Download Owner's manual of Bloomfield ELECTRONIC BREW CONTROL 1090 Coffee Maker for Free or View it Online on All-Guides.com. This version of Bloomfield ELECTRONIC BREW CONTROL 1090 Manual compatible with such list of devices, as: ELECTRONIC BREW CONTROL 1090, ELECTRONIC BREW CONTROL 1091, ELECTRONIC BREW CONTROL 1092, E.B.C. Dual Automatic Airpot Coffee Brewers 1092, E.B.C. Dual Automatic Thermal Coffee Brewers 1090

Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 1
1
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 2
2
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 3
3
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 4
4
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 5
5
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 6
6
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 7
7
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 8
8
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 9
9
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 10
10
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 11
11
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 12
12
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 13
13
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 14
14
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 15
15
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 16
16
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 17
17
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 18
18
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 19
19
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 20
20
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 21
21
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 22
22
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 23
23
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 24
24
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 25
25
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 26
26
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 27
27
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 28
28
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 29
29
Bloomfield ELECTRONIC BREW CONTROL 1090 Owner's manual - Page 30
30
INSTALLATION INSTRUCTIONS (continued)
NOTE: This equipment must be
installed to comply with
applicable federal, state and
local plumbing codes and
ordinances.
WARNING:
SHOCK HAZARD
Brewer must be properly
grounded to prevent possible
shock hazard. DO NOT
assume a plumbing line will
provide such a ground.
Electrical shock will cause death
or serious injury.
IMPORTANT: Do not connect
brewer to electrical power until
the tank is filled with water.
Pour water into the pour-over
opening until water flows from
the brew head.
IMPORTANT:
Supply power must match
nameplate for voltage and
phase. Connecting to the
wrong voltage will damage the
brewer or result in decreased
performance. Such damage is
not covered by warranty.
NSF requires that the brewer be able to be moved for cleaning
underneath. A flex line or loops of copper tubing will satisfy this
requirement. See Figure 2 below.
In some areas, local codes require a backflow preventer (check
valve) to be installed on the inlet water line. If a backflow
preventer is used, you must install a water hammer arrester in
the incoming line, between the backflow preventer and the
brewer inlet, as far away from the brewer as space will allow.
This will relieve the excessive back pressures that can cause
faucet leaks and solenoid malfunctions.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1
Check the nameplate to determine correct electrical service
required for the Brewer to be installed.
IMPORTANT: Before connecting to electricity, make sure
automatic brewers are connected to the water supply.
Brewers must be wired by an electrician, and require a dedicated
115/230V or 120/240V 20A circuit (50/60 Hz, L1, L2, Neutral,
plus ground). Remove front panel to gain access to terminal
block. Green terminal must be connected to a suitable building
ground. Circuit must be capable of 4000 Watts (model 1090 and
1092) or 7000 Watts (model 1091 and 1093).
See figure 3 at right.
IMPORTANT: Wiring must be installed in approved solid or
flexible conduit, and must be secured to the brewer with a strain
relief (to be provided by the installer).
Fig. 3 115/240V Terminal Block
5
Fig. 2 Water Supply Installation
645 75908 Owners Manual E.B.C. Dual Airpot/Thermal Brewer