YHC5150X FieldMate Handheld Communicator Getting Started Guide
Introduction
YHC5150X FieldMate Handheld Communicator is a full function HART
®
Communicator supporting Universal, Common Practice & Device Specific commands.
Recharging Cradle is not rated for intrinsic safety and should only be used in a non-hazardous area.
See the “Hazardous Area Use” section of the Control Drawing in the Instruction Manual IM 01R01A30-01EN.
Battery Pack Installation & Removal
Pack is held into the communicator by two standard 6-32 screws with hex sockets that require a 7/64” hex wrench. Do not over-tighten battery case screws
Installation: Set the communicator enclosure with the display downward on a flat stable surface. Rest the battery pack in the battery pack compartment of the enclosure leaving a ½”
gap between the battery pack and the connector on the communicator enclosure. Slide the battery pack upward along the enclosure until the connectors mate completely and the
screws are aligned with the threaded inserts on the communicator body. Thread the screws into the insert to complete the installation.
Removal: Reverse the order of the operations.
The battery pack contains an advanced battery fuel gauge that actively monitors the battery capacity and therefore does not require any “battery training” throughout the life of
the battery pack.
The Recharging Cradle is not intended to recharge a battery separately. To properly charge a battery pack it is required to be inserted into a communicator prior to being placed on
the charger.
Powering On the YHC5150X FieldMate Handheld Communicator
Push the power button for 1 full second, then release. After approximately 2 seconds a splash screen will appear & YHC5150X FieldMate Handheld Communicator application will load.
Connecting to a HART
®
Device
The main system menu is the initial menu at power turn on. It is also accessible from any HART
®
menu.
HART
®
Connection descriptions
Indicates that no device is detected in the active polling range. The communicator is still actively polling the HART
®
address range you have
selected in the HART
®
setup. If the poll address range is a single address, and a device is found at that address the communicator will
immediately initiate connection, and additional polling is terminated. If the poll address range is not a single address and a device is found the communicator will continually search
throughout the full range of addresses to find any available connections.
Indicates that multiple devices were found in the polling range and you must select which device to communicate with. Pressing the
yellow icon will bring up a list box with all devices that were found in the polling address range. Once you choose a device and press
“Accept”, the box will collapse and the communicator will initiate connection.
Indicates that the device selected is connecting and the Device Description (DD) is loading.
Initialization is complete and a device is actively connected to the HART
®
network. The communicator does not continue to poll for other
devices. If the green bar is selected the communicator will exit the system menus and go to the online HART
®
menu.
Online HART
®
Menu - (SDC-625)
HART
®
Device Menus are only accessible when a HART
®
communication enabled device is connected and communicating with the YHC5150X FieldMate Handheld Communicator.
Store/
Retrieve Configuratio
n
Batter
y Level, Time
Hot Key
There are four distinct areas on a
HART
®
menu (Top,
Middle Left, Middle Right, Bottom)
HART
®
Menu Path
System
Navigation
Online Hart
®
Device Menu
Device Status
Return to System Menu
Create Shortcut
Commit
Changes
User Created Shortcut
**
Please
,
read the User’s Manual for detailed description of all menus and features.
**
User defined test fields (such
as HART parameters like
Tag and Long Tag, file
names, and shortcut labels)
do not support multiple
language translations.
It is invalid to create a
shortcut on the home menu
(often labeled “Online”). If a
primary menu has
submenus (designated by 0
–MORE- in the tenth line)
the shortcut created will be
to the primary menu
regardless of the submenu
currently being displayed.
Charging Indicator
There is a multicolor light
on the recharging cradle.
This light indicates the
current charging mode.
Off
– No battery pack inserted,
or power disconnected
Solid Green
– Battery is charged
Flashing Amber
– Battery is charging
Solid Amber
– Battery temp out
of charging range
Flashing Red
– Battery fault
Solid Red
Charger fault
6-32 screws with
7/64” hexagonal
socket
µSD memory card
access
Battery
P
ack
Installation
&
R
emoval
Keys
, Direction Arrows
Key
,
Power
On/Off
Key
, Backlight
Do not over-tighten battery case screws.
Maximum torque should not exceed 7 in-lb.
Battery should be charged completely
(4.5 hours) before using the first time.
Keys
, Numeric
Keys
, Information and
Advance
HART
®
Connection
Display and Touch Screen
(No Stylus Required)
Keyboard
,
Full QWERTY
This card should only be replaced by Yokogawa part 1W-
9P780, or its successor, and only under the direction of
Yokogawa personnel. Use of a non-system memory card
will void safety
certifications.
System Navigation
(Touch the icon or Press the number)
1. Handheld Setup Icon
2. HART
®
Setup Icon
3.
System Info Icon
HART
®
C
onnections
Focus Pane
(Red Box)
HART
®
Polling Address Range Selection
Allows you to select a range of addresses to
poll, or to select a tag or long tag to use in
polling for a HART
®
enabled device.
System Menu
There are three distinct areas on a
System M
enu (Top, Center, Bottom
)
Battery/ Time
Repolling
Device
Information
Manufacture
Model:
Tag Info