1. INTRODUCTION
Universal Garage Door
Remote Control
Model G5M
Thank you for your purchase of the Skylink garage door remote control,
Model G5M. There are 3 different steps you need to set-up in order to
use this universal garage door remote control to operate your existing
garage door opener. These 3 steps are:
1) Frequency switch – select the correct frequency according to the
brand of your existing garage door opener.
2) Brand jumpers – place the brand jumpers at the correct position according
to the brand of your existing garage door opener.
3) Code setting – Set the jumper connectors on the Model G5M so that
they match the code setting of your existing garage door opener.
In this package, you should find a garage door remote control with 12V
alkaline battery, a mounting bracket and a clip.
Please follow the detailed instructions below in order to set-up the
Skylink Model G5M to work with your existing opener.
2. PROGRAMMING YOUR NEW TRANSMITTER
1a. Locate frequency switch on the top
of the transmitter. (See diagram A)
1b. Determine the brand of your garage
door opener and set the frequency
switch to the corresponding position.
(See chart 1)
Diagram A
USA
CANADA
A
390
390
B
315
318
C
310
315
D
300
310
1. SET FREQUENCY SWITCH
2a. To set the brand jumpers, open the
case with a coin (see diagram B).
2b. The Model G5M contains 2 brand jumpers and 12 code connectors
(see diagram C). The brand jumpers are located just above the
battery with markings “A” and “B”. There are 2 connectors, one is
placed on the “A” column, the other one is placed on the “B” column.
For each column, there is a connector. If the connector is placed on
the top and middle post of that column, that
column is set on “+”. If the connector is
placed on the middle and bottom posts, that
column is set on “-“. If the connector is
removed completely, that column is set on “0”
(see diagram C). In order for the Model G5M to
work with your existing garage door opener
(motor), you need to set the brand jumpers
based on the brand of your existing garage
door opener. Please set these 2 brand jumpers
“A” and “B” based on the brand jump ers setting
on chart 2. Please identify the group number
on chart 2 in order to determine which is the
next step to proceed.
Diagram B
2. SET BRAND JUMPER
Code connector Location
Brand Jumper
A = “-”
B = “+”
Diagram C
REMOVE JUMPER = “0”
BATTERY
2. PROGRAMMING YOUR NEW TRANSMITTER (CONT)
* Note:
For Genie
®
Intellicode
TM
& Overhead Code Dodger
TM
, if the brand
jumper for group 3 cannot operate your garage door opener properly,
please use setting A “-”, B “+”.
For garage door openers belonging to groups 1 to 5, please follow
step 3 of the procedures, this will complete the setup. No need to proceed
to step 4.
For garage door openers belonging to groups 6 to 0, you can
proceed directly to “Step 4 – Set Code Connector” after you have
successfully set the brand jumpers. Please skip step 3 below.
3a. If your existing garage door opener belongs to any brand from group
1, 2, 3, 4 or 5 then you should find a “learn” button from the garage door
opener (the unit with the motor located on the ceiling of your garage,
see diagram D). Press this learn button for approximately 2 seconds.
The LED light beside the learn button will go on and then press the
button on the Model G5M to activate it. The LED light on the garage
door opener will flash then go off.
The Model G5M is now programmed
to your existing garage door opener
and will operate your garage door.
Programming is now completed
and please refer to the “Battery”
section of this manual for battery
maintenance.
Diagram D
‘Learn’ Button
Garage Door
Opener (GDO)
3. LEARN CODE
Note:
Proceed to this step only if the brand of your garage door opener
belongs to either group 1, 2, 3, 4 or 5 on chart 2. Otherwise, proceed
to Step 4 - Set code connector.
Note:
Proceed to this step only if the brand of your garage door opener
belongs to either group 6, 7, 8, 9 or 0 on chart 2. Otherwise, proceed
to Step 3 - Learn code.
4a. If the brand of your garage door opener
belongs to groups 6 to 0, that means you
need to program the correct code setting
in order for the Model G5M to work with
your existing garage door opener. There
are 12 code connectors on 12 columns
from 1 to 12 (see diagram E). Each column
has one connector. (see diagram F)
4b. Set the connectors numbered 1 through 12 to match the code setting
of your existing transmitter or receiver. There are 2 places you can
find out the code setting from a column of small switches of your
existing garage door opener.
1) your existing transmitter (the unit you currently use to open your
garage).
2) the receiver of your garage door opener (the unit with the motor
mounted on the ceiling of your garage).
4. SET CODE CONNECTORS
Diagram F
Diagram E
Mounting
Bracket
Garage Door Remote Control
(Battery inside)
Clip
Chart 1
Chamberlain
®
Lift-Master
®
Sears
®
Wayne Dalton
®
Master Mechanic
®
Genie
®
Overhead
®
390MHz only
Linear
®
M-O-M
®
Stanley
®
Multi-Code
®
Martec/Teckey
®
Skylink
®
UR-100
Pulsar
®
/Allstar
®
/Allister
®
Linear
®
MegaCode
TM
Skylink
®
18 series
390 or 315
390 or 315
390 or 315
300 or 390
390
390
390
310
310
310
300 or 310
300
390
Brand of your opener
A or B
A or B
A or B
D or A
A
A
A
C
C
C
D or C
D
A
C or A
C or A
C or A
C or A
C or A
C or A
A
D
D
D
D
A
B
B
B
315 or 390
315 or 390
315 or 390
315 or 390
315 or 390
315 or 390
390
310
310
310
310
390
318
318
318
N/A
N/A
N/A
N/A
Group Brand Brand jumpers setting Proceed to
A B
1 Chamberlain
®
, Sears
®
, Lift-Master
®
(without DIP switches but with red, orange or purple + -
learn button)
2 Chamberlain
®
, Lift-Master
®
, Sears
®
, Wayne Dalton
®
, - 0
Master Mechanic
®
(without DIP switches but with
yellow, white, gray or green learn button)
3* Genie
®
Intellicode
TM
* (without DIP switches) + +
Overhead Code Dodger
TM
* (without DIP switches)
4 Linear
®
MegaCode
TM
(Canada only) 0 -
5 Skylink
®
18 series
(Canada only) 0 0
6 Genie
®
(with DIP switches), Overhead
®
+ 0
7 Chamberlain
®
, Lift-Master
®
, Sears
®
, Wayne Dalton
®
, - +
Master Mechanic
®
(with DIP switches)
8 Stanley
®
, Multi-Code
®
, Martec
®
- -
9 Linear
®
, Moore-O-Matic
®
0 +
0 Pulsar
®
/ Allstar
®
/ Allister
®
(Canada only) 0 -
Chart 2
Proceed
to Step 3.
Proceed
to Step 4,
skip Step 3.
Set switch
to position Frequency
USA
Set switch
to position
Frequency
CANADA