The Honeywell 5192 Series low profile, addressable V-Plex
smoke detectors deliver state-of-the-art features and
benefits in a cost-effective package. These detectors are
designed to provide open area coverage and are
compatible with Honeywell’s VISTA controls supporting
V-Plex technology.
An LED on the detector will blink periodically during normal
conditions, remain on steady during alarm and cease to
pulse if the chamber is out of acceptable sensitivity range.
An extremely powerful feature available within the 5192
Series is the Automatic Maintenance Alert/Reporting
capability – a feature normally found in today’s high end
analog addressable systems. The detectors continually
monitor their own sensitivity levels in addition to the basic
normal and alarm conditions. These HIGH and LOW
SENSITIVITY signals are communicated back to the
control, via the V-Plex addressable loop, to indicate locally
and at the central station that the detector may not be able
to detect smoke or may false alarm. This feature works
with VISTA-32FB, 128BP, 128FBP, 250BP, 250FBP, 40,
50P, 100-24 and FAP FA1600C, FA1660C and FA1700C.
More important is the cost saving associated with
Automatic Maintenance Reporting. The feature is an
approved alternate to NFPA 72 field sensitivity calibration
testing that require external test meters. This eliminates the
need to schedule inspections to determine detector
sensitivity/viability. Another important benefit of these V-Plex
(addressable) smoke detectors is their ability to operate on
existing wiring.
There is no need to run special twisted pair, data grade or
shielded wires, providing you with the right choice for all
your retrofit applications. That equates to cost savings in
time and materials!
• Low profile design
• V-Plex addressable loop device
• Automatic maintenance reporting
• Available with integral heat sensor
• Simple 2 wire installation
• DIP switch or serial number
programmable
• Lines on existing or
conventional wiring
FEATURES
The 5192 Series smoke detectors are designed to provide open area coverage and are well suited for most fire detection
applications. These smoke detectors are compatible with all Honeywell VISTA Fire and Burglary controls that support V-Plex
addressable loop technology. These agency listed alarm initiating devices support most commercial and residential applications. They are
suited for use in museums, hospitals, day care centers, retail stores, strip malls, schools, libraries, fast food chains, medical or
professional office suites and in factory and warehouse environments.
APPLICATIONS
5192SD/5192SDT
V-PLEX
®
SMOKE DETECTOR