Maytag 30" Installation Instructions Manual

Download Installation instructions manual of Maytag 30" Cooktop for Free or View it Online on All-Guides.com.

Brand: Maytag

Category: Cooktop

Type: Installation instructions manual for Maytag 30"

Pages: 32

Download Maytag 30" Installation instructions manual

Maytag 30
1
Maytag 30
2
Maytag 30
3
Maytag 30
4
Maytag 30
5
Maytag 30
6
Maytag 30
7
Maytag 30
8
Maytag 30
9
Maytag 30
10
Maytag 30
11
Maytag 30
12
Maytag 30
13
Maytag 30
14
Maytag 30
15
Maytag 30
16
Maytag 30
17
Maytag 30
18
Maytag 30
19
Maytag 30
20
Maytag 30
21
Maytag 30
22
Maytag 30
23
Maytag 30
24
Maytag 30
25
Maytag 30
26
Maytag 30
27
Maytag 30
28
Maytag 30
29
Maytag 30
30
Maytag 30
31
Maytag 30
32
8
8. Open the broiler door. Use a ³⁄₈" drive ratchet to lower the rear
leveling legs one-half turn. Use a wrench or pliers to lower the
front leveling legs one-half turn.
9. Adjust the leveling legs to the correct height. Leveling legs
can be loosened to add up to a maximum of 1" (2.5 cm). A
minimum of ³⁄₁₆" (0.5 cm) is needed to engage the anti-tip
bracket.
10. Move range into its final location, making sure rear leveling
leg slides into anti-tip bracket.
11. If installing the range in a mobile home, you must secure the
range to the floor. Any method of securing the range is
adequate as long as it conforms to the standards in the
“Location Requirements” section.
12. Continue installing your range using the following installation
instructions.
Make Gas Connection
Typical rigid pipe connection
A combination of pipe fittings must be used to connect the range
to the existing gas line. Your connections may be different,
according to the supply line type, size and location.
1. Apply pipe-joint compound made for use with LP gas to all
pipe thread connections.
2. Using a pipe wrench to tighten, connect the gas supply to the
range.
Typical flexible connection
1. Apply pipe-joint compound made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and F in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
A. Rear leveling leg
B. Front leveling leg
A
A Rear leveling leg
B
A. Pressure regulator
connection fitting
B. 90° elbow
C. Black iron pipe
D. Union
E. Nipple
F. Manual shutoff valve
G. ½" or ¾" gas pipe
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
G
E
F
C
D
A
B