Maytag 30" Installation Instructions Manual

Download Installation instructions manual of Maytag 30" Cooktop for Free or View it Online on All-Guides.com.

Brand: Maytag

Category: Cooktop

Type: Installation instructions manual for Maytag 30"

Pages: 32

Download Maytag 30" Installation instructions manual

Maytag 30
1
Maytag 30
2
Maytag 30
3
Maytag 30
4
Maytag 30
5
Maytag 30
6
Maytag 30
7
Maytag 30
8
Maytag 30
9
Maytag 30
10
Maytag 30
11
Maytag 30
12
Maytag 30
13
Maytag 30
14
Maytag 30
15
Maytag 30
16
Maytag 30
17
Maytag 30
18
Maytag 30
19
Maytag 30
20
Maytag 30
21
Maytag 30
22
Maytag 30
23
Maytag 30
24
Maytag 30
25
Maytag 30
26
Maytag 30
27
Maytag 30
28
Maytag 30
29
Maytag 30
30
Maytag 30
31
Maytag 30
32
9
3. Use a combination wrench and pliers to attach the flexible
connector to the adapters. Check that connector is not
kinked.
Complete Connection
1. Locate gas pressure regulator in the back of the range.
IMPORTANT: Do not remove the gas pressure regulator.
2. Check that the gas pressure regulator shutoff valve is in the
“ON” position.
IMPORTANT: The factory default setting is the “ON” position. If
the range does not work, verify that the valve is in the “ON”
position.
3. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
4. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
5. Remove cooktop burner caps and grates from parts
package. Align notches in burner caps with pins in burner
base. Burner caps should be level when properly positioned.
If burner caps are not properly positioned, surface burners
will not light. Place burners, burner caps and grates on the
cooktop.
6. Plug into a grounded 3 prong outlet.
Verify Anti-Tip Bracket Location
1. Check that the anti-tip bracket is installed:
Look for the anti-tip bracket securely attached to the
floor.
Slide the range back so the rear range foot is under the
anti-tip bracket.
Level Range
1. Place rack in oven.
2. Place level on rack and check levelness of range, first side to
side; then front to back.
3. If range is not level, pull range forward until rear leveling leg is
removed from the anti-tip bracket. Use ³⁄₈" drive ratchet and
wrench or pliers to adjust leveling legs up or down until range
is level.
4. Push range back into position.
5. Check that rear leveling leg is engaged in anti-tip bracket.
NOTE: Range must be level for satisfactory baking performance.
A. Pressure regulator
connection fitting
B. Use pipe-joint compound.
C. Adapter
D. Flexible connector
E. Adapter
F. Use pipe-joint compound.
G. Manual shutoff valve
H. ½" or ¾" gas pipe
A. Gas pressure regulator
A.
On position
B.
Off position
A. Closed valve
B. Open valve
C
E
G
H
A
D
F
B
A
A
B
A
B
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING