Viking VCSB5481 Series Technical Information

Download Technical information of Viking FDSB5481 Kitchen Appliances, Ranges for Free or View it Online on All-Guides.com.

Viking FDSB5481 Technical information - Page 1
1
Viking FDSB5481 Technical information - Page 2
2
Viking FDSB5481 Technical information - Page 3
3
Viking FDSB5481 Technical information - Page 4
4
Viking FDSB5481 Technical information - Page 5
5
Viking FDSB5481 Technical information - Page 6
6
Viking FDSB5481 Technical information - Page 7
7
Viking FDSB5481 Technical information - Page 8
8
Viking FDSB5481 Technical information - Page 9
9
Viking FDSB5481 Technical information - Page 10
10
Viking FDSB5481 Technical information - Page 11
11
Viking FDSB5481 Technical information - Page 12
12
Viking FDSB5481 Technical information - Page 13
13
Viking FDSB5481 Technical information - Page 14
14
Viking FDSB5481 Technical information - Page 15
15
Viking FDSB5481 Technical information - Page 16
16
Viking FDSB5481 Technical information - Page 17
17
Viking FDSB5481 Technical information - Page 18
18
Mode C Options (the following are
accessed
after
mode
C is entered), continued
Mode
C
Pa
rameter
Adjust Freezer
Upper
Temperature
Limit
Adjust Freezer
Lower
Temperature
limit
Adjust
Refrigerator
Upper
Temperature
limit
Adjust
Refrigerator
Lower
Temperature
limit
Values
-30
to
30F
in
IF
increments
-30
to
30F
in
IF
increments
33
to
50F
in
IF
increments
33
to
50F
in
IF
increments
Remarks and procedures
Pressand hold
MAX
FRZ
and whileholding that keypressand hold
HIGHER
key
for
three
(3)
seconds.
The
display
will
initially
show
"FUL".
Adjustment
-
Press
HIGHER
or
LOWER
key
onceto
view
and
adjust
value.
While the valueisbeing displayed, the °F indicator shallbe illu
minated. Factory setting is 7.
Exit- Press
ACTIVATE
CONTROLS
key once. The display will show
"PrC" to indicate control is still in Program Mode C.
Press and hold MAX FRZand while holding that key press and hold
LOWER
keyfor three (3)
seconds.
The
display
will
initially
show
"FLL".
Adjustment
-
Press
HIGHER
or
LOWER
key
once
to
view
and
adjust
value. While the value isbeingdisplayed, the °Findicator shall be illu
minated. Factory setting is -5.
Exit - Press
ACTIVATE
CONTROLS key once. The display will show
"PrC" to indicatecontrol isstill in Program Mode C.
Press and hold MAX
REF
and while holding that key press and hold
HIGHER
keyfor three
(3)
seconds.
The
display
will
initially show
"rUL".
Adjustment - Press
HIGHER
or
LOWER
keyonce to viewand adjust
value. While the value is being displayed, the °F indicator shall be illu
minated. Factory setting is 47.
Exit - Press ACTIVATE CONTROLS key once. The display will show
"PrC"
to
indicate
control
is still in
Program
Mode
C.
Press and hold
MAX
REF
and while holding that key press and hold
LOWER
key for three (3) seconds. Thedisplay
will
initiallyshow
"rLL".
Adjustment - Press HIGHER or LOWER key once to view
and
adjust
value. While the value is being displayed, the °F indicator shall be illu
minated. Factory setting is 33.
Exit - Press
ACTIVATE
CONTROLS key once. The display will show
"PrC" to indicate control isstillin Program ModeC.
Exiting
Program
Mode
C
1.
Press
and
hold
the
ACTIVATE
CONTROLS
key for
three
(3)
seconds.
The
control will
change
from
Program
Mode
C to Normal
Mode
and any
changes
made
in
Program
Mode
will
be
saved
to EE
PROM.
2.
Press
the
ACTIVATE CONTROLS key
once.
The
control
will
change
from
Program
Mode C to
Pro
gram
Mode
A
and any
changes
made
in
Program
Mode
will
be
saved
to
EEPROM.
3. If
the
keypad
is
not
used
for
ten
(10)
minutes,
the
control will
automatically
change
from
Program
Mode
C to Normal
Mode
and
any
changes
made
in
Program
Mode will
not
be
saved
to
EEPROM.
10