Xpelair XHR150PC Installation Instructions Manual

Download Installation instructions manual of Xpelair XHR150HP Fan for Free or View it Online on All-Guides.com.

Brand: Xpelair

Category: Fan

Type: Installation instructions manual

Model: Xpelair XHR150HP , Xpelair XHR150PC

Pages: 10

Download Xpelair XHR150HP Installation instructions manual

Xpelair XHR150HP Installation instructions manual - Page 1
1
Xpelair XHR150HP Installation instructions manual - Page 2
2
Xpelair XHR150HP Installation instructions manual - Page 3
3
Xpelair XHR150HP Installation instructions manual - Page 4
4
Xpelair XHR150HP Installation instructions manual - Page 5
5
Xpelair XHR150HP Installation instructions manual - Page 6
6
Xpelair XHR150HP Installation instructions manual - Page 7
7
Xpelair XHR150HP Installation instructions manual - Page 8
8
Xpelair XHR150HP Installation instructions manual - Page 9
9
Xpelair XHR150HP Installation instructions manual - Page 10
10
REMOTE CONTROL
TRANSFORMER
Note: The transformer unit should be connected to the
mains supply through a fused double pole isolating switch
maximum 5 amps.
Min 6 inches
Installation Instructions
If working above Ground Floor level, appropriate safety precautions must be observed.
WARNING
EYE PROTECTION MUST BE WORN DURING ALL DRILLING AND CHISELLING OPERATIONS
Safety First
The Heat Recovery Ventilator is a ”SELV” (Safety Extra Low Voltage) ventilator which operates at 12 volts AC. Under no
circumstances must this be connected directly to the mains supply. Damage so caused is not covered by the warranty.
The low voltage used by the ventilator must be provided by the isolating transformer. A typical layout of installation is
shown below.
The Heat Recovery Ventilator can be used in any room which has an outside wall open to fresh air. It is particularly
useful in the bathroom, kitchen or laundry room where high levels of moisture are generated. It can also be used in the
lounge, dining room or any bedroom to provide a fresh air supply to reduce dust-mite, eliminate mould growth or
dampness and condensation and to provide warmed fresh air.
April 2000
These appliances are intended for connection to fixed wiring.
Check that the electrical rating shown on the transformer matches the mains supply.
All installation must be supervised by a qualified Electrician.
Installation and wiring must conform to current IEE Regualtions(UK), local or appropriate regulations
(other countries)
The product must be supplied by a double pole isolating switch with a minimum contact gap of 3mm.
The product is double insulated and does not require earth connection. A parking terminal is provided to
ensure continuity of external protective wiring only, and when used must comply with the relevant regulations
WARNING
THESE APPLIANCES ARE DOUBLE INSULATED AND DO NOT REQUIRE AN EARTH CONNECTION
If you have any queries before installing this product or after it has been installed, please contact GDA
Applied Energy, Customer Services - see back cover. Customers outside the UK should contact their
local Xpelair distributor.
Xpelair Heat Recovery Ventilation Range- XHR150PC and XHR150HP
Xpelair Heat Recovery Unit have the following features: XHR150PC Integral Pull Cord
Heat Recovery Ventilator
VENTILATOR
Eclipse - Oxplaire 12/4/00 6:51 pm Page 1