York YZH02411 Technical Manual

Download Technical manual of York YZH02411 Heat Pump for Free or View it Online on All-Guides.com. This version of York YZH02411 Manual compatible with such list of devices, as: YZH02411, YZH03611, YZH04811, YZH06011

Brand: York

Category: Heat Pump

Type: Technical manual

Model: York YZH02411 , York YZH03611 , York YZH04811 , York YZH06011

Pages: 52

Download York YZH02411 Technical manual

York YZH02411 Technical manual - Page 1
1
York YZH02411 Technical manual - Page 2
2
York YZH02411 Technical manual - Page 3
3
York YZH02411 Technical manual - Page 4
4
York YZH02411 Technical manual - Page 5
5
York YZH02411 Technical manual - Page 6
6
York YZH02411 Technical manual - Page 7
7
York YZH02411 Technical manual - Page 8
8
York YZH02411 Technical manual - Page 9
9
York YZH02411 Technical manual - Page 10
10
York YZH02411 Technical manual - Page 11
11
York YZH02411 Technical manual - Page 12
12
York YZH02411 Technical manual - Page 13
13
York YZH02411 Technical manual - Page 14
14
York YZH02411 Technical manual - Page 15
15
York YZH02411 Technical manual - Page 16
16
York YZH02411 Technical manual - Page 17
17
York YZH02411 Technical manual - Page 18
18
York YZH02411 Technical manual - Page 19
19
York YZH02411 Technical manual - Page 20
20
York YZH02411 Technical manual - Page 21
21
York YZH02411 Technical manual - Page 22
22
York YZH02411 Technical manual - Page 23
23
York YZH02411 Technical manual - Page 24
24
York YZH02411 Technical manual - Page 25
25
York YZH02411 Technical manual - Page 26
26
York YZH02411 Technical manual - Page 27
27
York YZH02411 Technical manual - Page 28
28
York YZH02411 Technical manual - Page 29
29
York YZH02411 Technical manual - Page 30
30
York YZH02411 Technical manual - Page 31
31
York YZH02411 Technical manual - Page 32
32
York YZH02411 Technical manual - Page 33
33
York YZH02411 Technical manual - Page 34
34
York YZH02411 Technical manual - Page 35
35
York YZH02411 Technical manual - Page 36
36
York YZH02411 Technical manual - Page 37
37
York YZH02411 Technical manual - Page 38
38
York YZH02411 Technical manual - Page 39
39
York YZH02411 Technical manual - Page 40
40
York YZH02411 Technical manual - Page 41
41
York YZH02411 Technical manual - Page 42
42
York YZH02411 Technical manual - Page 43
43
York YZH02411 Technical manual - Page 44
44
York YZH02411 Technical manual - Page 45
45
York YZH02411 Technical manual - Page 46
46
York YZH02411 Technical manual - Page 47
47
York YZH02411 Technical manual - Page 48
48
York YZH02411 Technical manual - Page 49
49
York YZH02411 Technical manual - Page 50
50
York YZH02411 Technical manual - Page 51
51
York YZH02411 Technical manual - Page 52
52
TECHNICAL GUIDE
AFFINITY
SPLIT-SYSTEM HEAT PUMPS
18 SEER – R-410A
MODELS:
YZH024 THRU 060*(C)
(2 THRU 5 NOMINAL TONS)
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Standard 5-year limited parts warranty.
10-year limited compressor warranty.
Premium System Warranty - Limited lifetime compressor
when matched with an approved York Affinity furnace or
UPG air handler and coil.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replace-
ment or closing for new home construction.
LISTED
505591-YTG-A-0909
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The 18 SEER Series unit is the outdoor part of a versatile climate
system. It is designed with a matching indoor coil component
from Johnson Controls Unitary Products. Available for typical
applications this climate system is supported with accessories
and documents to serve specific functions.
FEATURES
Superior Coil Protection – A stamped decorative metal coil
guard completely protects coil from debris and other large
damaging material while a polymer mesh further protects the
coil against smaller particles.
Isolated Compressor Compartment – A molded composite
bulkhead isolates the compressor from the rest of the unit
reducing sound and vibration.
Protected Compressors – Each compressor is protected
against high and low pressure as well as excessive tempera-
ture. This is accomplished by by the simultaneous operation of
a high pressure relief valve and temperature sensors which
protect the compressor if undesirable conditions occur.
Environmentally Friendly Refrigerant – Next generation
refrigerant R-410A delivers environmentally friendly perfor-
mance, with zero ozone depletion.
Durable Finish – Automotive quality finish provides the ulti-
mate protection from harmful U.V. rays as well as rust creep
ensuring long-lasting high quality appearance. A powder-paint
topcoat is applied over a baked-on primer, using a galvanized,
zinc coated steel base material. The result is a finish that has
been proven in testing to provide 33% greater durability than
conventional powder-coat finishes.
Lower Installed Cost – Designed to provide enhanced
installability by featuring a slide-down control compartment
allowing easy access to control components along with angled
service valves to reduce overall installation time and cost.
Low Operating Sound Levels – A fan design boasting tech-
nology adapted from aeronautic and defense engineering pro-
vides for whisper quiet operation by allowing airflow to flow
smoothly and efficiently across the fan tips.
Filter-Drier – A factory installed, solid core liquid line filter-
drier filters harmful debris and moisture from the system.
Easy Service Access – A full end, full service, access panel
with handle makes for easy entry to internal components.
Long Lasting Operation – Strong and durable composite
base pan provides added strength while resisting rust and cor-
rosion as well as reducing sound and vibration.
QuietDrive
TM
system - The swept-wing fan, composite base
pan, isolated compressor compartment and two-stage com-
pressor are engineered as a system to reduce overall sound to
a mere whisper.
Complete System Control – All models utilize the exclusive
microprocessor based, on-demand, defrost control system.
This system provides optimal comfort, efficiency, and constant
montoring of the entire system for reliable operation. defrost
cycles occur only when necessary. an adjustable balance point
insures supplemental heat is brought on only when required to
meet the space load, for optimum efficiency and reliability.
In the event improper operating conditions occur (high temper-
ature and/or high pressure), the unit will automatically shut
down to protect the refrigeration system, and switch to back-up
heat. On-board diagnostic LED’s guide the technician to the
source of the problem, and an output signal from the control to
the thermostat will alert the homeowner. The control also fea-
tures non-volatile memory, which preserves trouble codes in
the event of power loss. An anti-short cycle timer extends the
life of the compressor by preventing short-cycling.
Agency Listed - U.L. and C.U.L. listed - approved for outdoor
application. The unit is certified in accordance with the Unitary
Small Equipment cerification program, which is based on ARI
Standard 210/240.