Vaccon VPI-90H Operating Instructions
Download Operating instructions of Vaccon VPI-90H Power Pump for Free or View it Online on All-Guides.com.
Installaon Instrucons:
Vaccon’s VPI-90H in-line venturi vacuum pump features the air supply port and
vacuum port on the same axis. Unlike standard venturi vacuum pumps where
the vacuum port is 90 degrees from the supply port, the VPI-90H’s can be
aached vercally to a roboc end of arm tool in a single or densely populated
array to accommodate any size, shape and weight of product being handled.
1. Install in-line vacuum pump to your mounng hardware, end-of-arm-tool, extrusion, etc.. The oponal
panel mount nut can be used to secure the pump to a panel. The exhaust port has a 5/8-18 UNF male
thread. The panel through hole should be at least ⅞” [21 mm].
2. Aach air line to air supply port. Aach vacuum line to vacuum port (when not directly aaching a
vacuum cup to the port). See chart below for minimum recommended sizes.
Technical Brief: Vacuum System Design:
Choosing The Correct Sized Tubing
Proudly Made In The USA
© 2014 Vaccon Company
9 Industrial Park Road, Medway, MA 02053 Phone: (508) 359-7200, US (800) 848-8788 Fax: (508) 359-0177
Visit Us Online at www.vaccon.com or email us at info@vaccon.com
Technical Brief: How Vacuum Pumps WorkOperating Instructions: VPI-90H
Inline Venturi Pump
Principles of Operaon
Vacuum is produced by forcing compressed air through a
liming orifice (nozzle). As the air exits the orifice it expands,
increasing in velocity to supersonic speed before entering
the venturi secon (diffuser). This creates a vacuum at the
vacuum inlet port located between the nozzle and diffuser.
The nozzle and diffuser combine to create a venturi vacuum
cartridge. The precise fit of the nozzle to the diffuser is
crical to the pump funconing properly.
Vacuum
Port
Oponal
Sensor / Switch
Oponal Panel
Mount Nut
Port Plug
Air Supply
Port
Exhaust Port
(boom)
Notes: Recommended sizes are based on tubing with
0.062" [1/16", 1.5 mm] wall polyethylene and
polyurethane tubing. Vaccon discourages the use of
quick disconnect fings on all connecons.
Air Supply Port
Threads
Recommended
Air Supply Line
(outer diameter)
¼" Push-To-Connect ¼"
⅛ NPT ¼"
Panel
Mounng
Threads
Recommended
Mounng Hole
⅝-18 UNF ⅞" [21 mm]
Vacuum Port
Threads
Recommended
Vacuum Line
(outer diameter)
VPI-90H
Vacuum
Exhaust
Air
Supply
Vacuum