Campbell VWANALYZER User Manual

Download Operation & user’s manual of Campbell VWA Measuring Instruments for Free or View it Online on All-Guides.com.

Brand: Campbell

Category: Measuring Instruments

Type: Operation & user’s manual

Model: Campbell VWA , Campbell VWANALYZER

Pages: 2

Download Campbell VWA Operation & user’s manual

Campbell VWA Operation & user’s manual - Page 1
1
Campbell VWA Operation & user’s manual - Page 2
2
Tips:
Return to the Main Menu by pushing the left soft key several times.
Carry spare batteries (5-AA) in the carrying case.
A continuous measurement can display engineering units when linked to a Site/Sensor
with an engineering unit conversion applied.
Leave 1–2 mm of exposed sensor wire on datalogger/multiplexer wiring for VWA
connection . Always disconnect automated system power prior to VWA connection.
Denitions:
Sensor: An individual vibrating wire sensor. A VWA can store up to 880
unique sensors (40 sites, 22 sensors/site).
Site: A project or geographic location containing up to 22 sensors.
User: Operator name and information.
Wiring Guide
VWA Cable Common Sensor Sensor
-RED -ONG Cable Colors
1
Description
Red
2
Orange
2
Red or Orange VW Gage
Black
2
Orange
2
Black White w/Orange VW Gage
Green
2
Blue
2
Green or Blue Therm/RTD
White
2
Blue
2
White White w/Blue Therm/RTD
Blue Yellow Bare/Clear Drain Wire
1
If sensor wiring does not match the table, refer to the sensor manufacturer manual to determine the VW gage
wire leads. Some sensors may not have a thermistor or RTD (temperature measurement).
2
Vibrating wire leads are interchangeable (black and red instead of red and black); thermistor leads are similarly
interchangeable.
Read & Record
There are three options to save data when using Read & Record.
Single is used when sensors won’t be repeatedly measured in the future (installation
record, baseline reading, troubleshooting).
Site/Sensor is used when sensors will be repeatedly measured and data needs to be
linked to a site. Site/Sensor data is viewable in the eld for historical comparison.
Continuous measures a single sensor at a user dened interval ranging from 1 second
to 15 minutes. Used to document installations, live eld testing (push-in-piezometer,
well pump test, sensor response, etc.), and for troubleshooting.
Notes:
Measurements are not pressure or temperature compensated.
Users can view all data. Sites are not user specic.
See Measurement Screens for an explanation of displayed measurement results.
Sites, Sensors, and Users can be created and edited either on the VWA, or with a PC and
keyboard using VwProjects.
Meet the Vibrating Wire Analyzer
Meet the Vibrating Wire Analyzer (VWA), the best vibrating wire (vw) eld reader
available. Field ready to quickly measure a sensor, save data, and communicate
results with custom PDF reports and spreadsheet output. Measurements are
geo-located with the integrated GPS allowing the VWA to verify locations and
walk you to your sensors. The large color display and VSPECT
TM
technology
1
create
condence that you are getting the best measurement possible both in the eld
and in the oce. , when your measurements matter.
1
Protected under U. S. Patent No. 7,779,690
Data Retrieval
Files are transferred to a PC from the VWA using the USB port . Measurement data collected
with the Read & Record option is saved as a PDF and/or CSV le. A printable report (PDF) com-
municates results quickly and professionally. Raw data les (CSV) can collect multiple sensors
(site) in a single le for additional spreadsheet analysis and reporting.
1 Export CSV les (optional)
Navigate to the Main Menu. See Operation.
Select Data. Choose and export CSV les.
2 Connect VWA to a PC with USB
Connect a PC to the VWA with a USB Mini-B cable.
Power is supplied through the USB-PC connection.
3 Copy les to PC
Find the USB ash memory device (VWA) on the PC.
Data les are stored in either the PDF Reports or CSV Data folder.
Copy les to the PC.
PDF Ready to print PDF reports
Reports Field documentation
CSV Multiple measurements in one le
Data Spreadsheet analysis
4 Eject VWA from PC
Eject the VWA from the PC prior to disconnecting the USB cable.
VwProjects
VwProjects is a free software package for easier setup of Sites, Sensors, and Users with a PC.
VwProjects can be downloaded and installed from the VWA memory or from the internet, see
Downloads.
VwProjects is used to create and edit a project le that contains information about Sites, Sen-
sors, and Users. Project les can be used to back up or transfer information to other VWA devices.
See Using VwProjects for details about creating, editing, and transferring project les.
Notes:
A project le contains information about Sites, Sensors, and Users. Measurement
data is saved in the PDF and CSV les, and is NOT saved or transferred in a project
le.
You can preview a report title block when creating or editing a user in
VwProjects.
File Types
The following les are created or used with the VWA. Files are transferred with a USB connection
(see Data Retrieval).
PDF: Measurement Reports created using Read & Record.
CSV: Created by the VWA with Read & Record, use for further spreadsheet analysis; see
Data Retrieval.
VWA: A project le contains information about Users, Sites, and Sensors. Created in the
VWA or with VwProjects.
OBJ: Operating system le, created by Campbell Scientic. See Downloads.
MANUAL
Info
Link
9/2017
manual pn: 31913
Caution
Avoid contact with water, see Precautions
Transport/store in carrying case
Measurements are not pressure or temperature corrected
!
Downloads
Visit www.campbellsci.com/vwanalyzer to download:
VwProjects software
Updated operating systems (updated Sensor Library)
Manual (this document)
FIELD
QUICK TOUR
Vibrating Wire Analyzer
1 Power
1
, left soft key
2
2 Right soft key
2
3 Enter/select
3
4 Menu navigation arrows (4)
5 Serial number (SN)
6 Battery door
7 Battery door screws (2)
8 Elastic strap connection (2)
9 Measurement cable
10 USB port (PC connection)
11 Measurement cable connection
1
Hold (2–3 s) to turn o
2
Soft keys select the displayed screen
option (when present)
3
Selects the highlighted option
1
2
3
4
5
6
7
8
9
10
11
OFFICE
PDF Reports
12 User specic title
1
13 Project Information
1
14 User-Dened Inputs
15 VSPECT Diagnostics
2
16 Field Notes
17 Sensor Frequency
18 Resistance (Thermistor/RTD)
19 Frequency Spectrum graph
2
20 9 Time Series graph
2
1
Entered manually or with a PC,
see VwProjects for details.
2
The VSPECT Measurement section
explains how to use and understand
VSPECT data.
12
13
14
15
16
17
18
19
20
Operation
1 Turn on the VWA
Install/replace batteries as needed (5-AA)
Push power button
2 Select/Create User
Links user information to specic measurements
User information is documented on PDF reports
3 Connect Sensor (if measuring)
Connect measurement cable . Keyed connector, do not force
Match sensor and measurement cable colors . See Wiring Guide
4 Navigate the Main Menu
Return to the Main Menu by pushing the left soft key several times.
1
11
9
Read:
Measure a sensor quickly,
Data is NOT saved
Read & Record:
Measure a sensor,
Data is saved
see Read & Record
Data:
Export data to CSV le, or view saved data
see Data Retrieval
Settings:
Change system, measurement, or power settings
1
9
10
10
12
Quality
• PDF Reports
• Field Ready
9
Link
Read &
Record
Read
Data
Settings
Vibrating Wire Analyzer
Data SettingsRead Read &
Record
1
6