Danfoss FH-WC Installation Instructions

Download Installation instructions of Danfoss 088H012800 Controller, Control Unit for Free or View it Online on All-Guides.com.

Brand: Danfoss

Category: Controller , Control Unit

Type: Installation instructions

Model: Danfoss 088H012800 , Danfoss FH-WC

Pages: 2

Download Danfoss 088H012800 Installation instructions

Danfoss 088H012800 Installation instructions - Page 1
1
Danfoss 088H012800 Installation instructions - Page 2
2
1
Specification FH-WC
Code number 088H012800
Hard-wired control box for
underfloor heating
Number of zone outputs for
thermal actuators
8
Maximum number of actuator
per zone
2
Zone outputs - voltage 230 Vac, 50 Hz
Zone outputs (2) -
max rating
3W
Night set-back channels (1) 2
Voltage free relay output for
interlocks
2 x SPST
Voltage rating of interlock relay 230 Vac, 50 Hz
Current rating of interlock relay 2 Amps, inductive
Power supply 230 Vac, 50 Hz
Max ambient temperature 50°C
Dimensions, mm 314w x 110h x 61d
(1) Night set-back requires separate time control
(2) Maximum 2 actuators per zone
FH-WC Hardwired Underfloor Heating Connection Box
Installation Instructions
System Schematic
Mounting
Mains in
Interlock
Interlock
ROOM THERMOSTATS
FH-WC WIRING BOX
MANIFOLD
THERMAL
ACTUATORS
Zone 1
Zone 2
Zone 3
Cable Access: Thermostats, Interlock and Mains
FH-WC Hard Wired Box
Cable Access: Thermal Actuators