Danfoss KP 15A Installation manual - Page 1
1
Danfoss KP 15A Installation manual - Page 2
2
Installation Guide
Pressure Control
Types KP 15, KP 15A, KP 17W, KP 17B, KP 17WB
© Danfoss A/S (AC-MCI / jmn), 2012-11 DKRCC.PI.CD0.A4.02 / 520H6074 1
060R9753
060R9753
Refrigerants
Ambient temperatures / Mounting requirements
KP 15, KP 17 KP 15, KP 17 KP 15A
KP 15, 17W, 17B, 17WB:
HCFC and non-ammable HFC
KP15A:
R717, HCFC and non-ammable HFC
Connections
Mounting
t
1
min. KP 15: -40 °C (-40 °F)
t
1
min. KP 17: - 25 °C (-13 °F)
t
1
max.: 65 °C (149 °F)
Relative humidity RH: 30 – 98%
Vibrations resistance: 4 g (10 – 1000 Hz)
Type Regulation range Max. working pressure PS/MWP
KP 15
LP: -0.2 – 7.5 bar
HP: 8 – 32 bar
17 bar / 245 psig
35 bar / 510 psig
KP 15
LP man. reset
LP: -0.9 – 7 bar
HP: 8 – 32 bar
17 bar / 245 psig
35 bar / 510 psig
KP 17
LP: -0.2 – 7.5 bar
HP: 8 – 32 bar
17 bar / 245 psig
35 bar / 510 psig
Test pressure (P
test
)
Enclosure
max. 3 mm
(
1
/
8
in.)
B: Enclosure IP30
(EN 60529)
C: Enclosure IP44
(EN 60529)
A: 8 – 32 UNC (M4)
Max. 100 °C
(212 °F)
15% Ag
p
test
max.
20 bar (285 psig)
PS/MWP
p
test
max.
35 bar (510 psig)
PS/MWP