Videx 316C Installation Instructions Manual
Download Installation instructions manual of Videx 316C Power distribution unit for Free or View it Online on All-Guides.com.
Brand: Videx
Category: Power distribution unit
Type: Installation instructions manual for Videx 316C
Pages: 8
66251700-EN - V1.1 - 31/10/16
1
Accessories
Art.316C - Installation instructions
Art.316C VX2200 - RJ-45 A/V distribution box
Fig. 1
66
77
25
CA
B
Fig. 2
DESCRIPTION
Due to the popularity of CAT5 cable for use on video intercom sys-
tem Videx have developed the Art.316C, a 4 way distribution box
with RJ-45 connections for the VX2200 6 wire bus video system.
It distributes the power (+ & –), the bus (L & –) and the video
(V1 & V2) from the main bus to 4 apartment outputs with RJ-45
connector.
The distributor also include an in and an out connection to con-
nect multiple Art.316C devices on the same bus.
The main bus connections include both RJ-45 and terminal con-
nections should a larger cable be required for the main bus en-
abling distanced of up to 400m.
LEGEND
A
Power LED.
When o this indicates there is no voltage between the ter-
minals “+” (plus) and “–” (minus).
Check that the wires are not interrupted or that the +20Vdc
power supply unit is connected to mains.
B
BUS LED.
When o this indicates there is no bus voltage which could
be he result of a short, a broken wire or if there is no master
door panel or concierge connected.
C
Video line termination switch.
End of line termination for the video. This should be set to “C”
(Closed) on the end of line device only.
KEY FEATURES
• Allows the installer to use standard CAT5 cable crimped to an RJ-45 plug
• 1 input / 1 output RJ-45 connection or standard 6 wire screw terminals
• 4 RJ-45 outputs to connect directly to 6000 Series monitors
• 1 switch to terminate the impedance of the video signal (End of Line)
• 2 fault diagnostic LED’s to indicate bus and power.
MATCHING SIGNALS OVER CAT5
EIA/TIA568B
1
2
3
4
5
6
7
8
o
O
g
B
b
O
br
BR
8
7
6
5
4
3
2
1
BR
br
G
b
B
g
O
o
EIA/TIA-568B
RJ-45 pin VX2200 Signal
1 and 2 (white-orange / orange) L
3 and 4 (white-green / blue) –
5 and 6 (white-blue / green) +
7 (white-brown) V1
8 (brown) V2
EIA/TIA568A
1
2
3
4
5
6
7
8
g
G
o
B
b
O
br
BR
8
7
6
5
4
3
2
1
BR
br
O
b
B
o
G
g
EIA/TIA-568A
RJ-45 pin VX2200 Signal
1 and 2 (white-green / green) L
3 and 4 (white-orange / blue) –
5 and 6 (white-blue / orange) +
7 (white-brown) V1
8 (brown) V2
NOTE: DO NOT USE CROSS OVER CABLES.
IMPORTANT NOTE: SOLID COPPER CABLES MUST BE USED. COPPER COATED STEEL CCS AND COPPER COATED
ALUMINIUM CCA CAN NOT BE USED ON THE SYSTEM.
TECHNICAL SPECIFICATION
Housing/Mounting: ABS plastic box / surface mount
Power Supply: 20V dc
Power consumption: Stand-by: 8mA Max: 40mA
Working Temperature: -10 +50 °C
ENG