Specifications
MIXPLUS MIXPLUSIND
Power Supply 230v-50Hz 110v-50Hz
Motor 1600W 1400W
RPM (no load) 180-460/300-750 rpm 0-480/0-800 rpm
Number of Gears 2 2
Mixing Paddle Diameter 140mm 140mm
Thread for Paddle Mixer
M14x2 M14x2
Weight 5kg 5kg
Q.E.P. Co UK Ltd is committed to a continuing program of product
improvement. Consequently, please be advised that specica-
tions, performance, appearance, and dimensions of QEP/Vitrex
products are subject to change without notice. For more up-to-
date information about our range of products, please contact
our Customer Service
Ofce on +44 (0)1253 789180 or your local distributor.
For further information or advice, please call the Vitrex Technical Helpline on
+44 (0) 1253789180.
This Power Mixer has been manufactured to a high quality standard. It is guaranteed against faulty materials and
workmanship for 12months from the date of purchase. Any claim must be accompanied by a valid till receipt as proof of purchase.
A faulty machine will either be repaired or replaced free of charge. If a direct replacement is not available, an alternative to the
same or greater value/specication will be offered.
This guarantee does not cover machine defects caused by or resulting from:
a) Misuse, abuse or neglect, b) Trade, Professional or hire use, c) Repairs attempted by anyone other than our authorised repair
agent, d) Ingress of foreign objects, substances or accident
In the unlikely event of a fault occurring, contact should be made through the Vitrex Technical Helpline +44 (0) 1253 789180
The above guarantee is only valid within the UK and does not affect your statutory rights.
The guarantor is Q.E.P. Co. UK Ltd., Everest Road, Lytham St. Annes, Lancashire, FY8 3AZ (Registered No. 04988177 England).
CARE AND MAINTENANCE
Remove the plug from the socket before carrying out any adjustment, servicing or
maintenance.
Your power tool requires no additional lubrication or maintenance.
Always store your power tool in a dry place.
If the supply cord is damaged, it must be replaced by the manufacturer,
their service agent or similarly qualied persons in order to avoid a hazard.
If a fault can not be rectied, return the mixer to an authorised dealer for repair.
Cleaning
Keep the safety devices, ventilation slots and motor housing as free of dirt and dust
as possible.
Clean the unit by rubbing it with a clean cloth or blow it clean using low-pressure
compressed air.
We recommend that you always clean the unit immediately after using it.
Clean the unit regularly by rubbing it with a damp cloth and a little soft soap.
Do not use cleaners or solvents; these will attack the plastic parts in the unit.
You must also ensure that water cannot get into the inside of the unit.
Carbon brushes
If excessive sparking occurs you must have the carbon brushes checked by a
qualied electrician.
CAUTION!
Brushes should only be changed by a qualied electrician.
Maintenance
There are no parts tted inside the unit that require maintenance.
For your own safety, never remove parts or accessories during maintenance. In
case of fault or damage, repairs should only be carried out by a specialist engineer
or by the manufacturer.
Environmental protection
Do not dispose of in general household
waste. Instead dispose of in an
environmental friendly way, contact your
local recycling centre of council for advice.
Please take the care of the environment
very seriously.
9. CORRECTIVE ACTION IN CASE OF FAILURE
(1) The operating switch is switched on, but the motor is
not working.
Wires in the mains plug or in the socket are loose.
Have socket and plug checked or repaired.
The switch is faulty.
Have the switch replaced.
(2) The operating switch is switched on, but unusual
noises can be heard, the motor is not working or only
very slowly.
Switch contact has failed.
Have the switch replaced.
Component jammed.
Have the electric tool checked or repaired.
The motor is dragging.
Use lower gear during the task.
(3) Motor gets hot.
Foreign substances have got inside the motor.
Have the foreign substances removed.
Lack of or contaminated lubrication grease.
Have lubricating grease applied or replaced.
Pressure too high
Use lower gear during the task.
(4) Frequent or strong sparks on the commutator.
Short circuit on the armature.
Have the armature replaced.
Carbon brushes worn out or jammed
Have the carbon brushes checked.
Rough running of the commutator.
Have the surface of the commutator cleaned or
ground.
Repairs should only by carried out a specialist engineer or by the manufacturer.