Red Lion IndustrialPro SN-6621 Quick Start Manual

Download Quick start manual of red lion IndustrialPro SN-6601 Network Router for Free or View it Online on All-Guides.com.

red lion IndustrialPro SN-6601 Quick start manual - Page 1
1
red lion IndustrialPro SN-6601 Quick start manual - Page 2
2
CONNECT. MONITOR. CONTROL. © 2014 Red Lion Controls. All Rights Reserved 1
QUICK START GUIDE
IndustrialPro
TM
Cellular Router
CDMA SN-6621 or SN-6601
UNPACKING INSTRUCTIONS
1. Unpack the Red Lion unit and verify the following components are
enclosed for the IndustrialPro Router: SN-6621 or SN-6601 and
this Quick Start Guide.
Antennas and power supply sold separately
CDMA MODELS SN-6621 OR SN-6601
SN-6621-S (SPRINT); SN-6621-V (VERIZON); SN-6621-US (US
CELLULAR) - units are carrier specific
1. The unit will need to be activated with a cellular carrier. If not, con-
tact your cellular carrier and provide them with the ESN number
located on the bottom label of the unit.
2. An antenna with an SMA connector should be connected to the
router. This antenna should meet the following specifications:
Dual-band 800 & 1900 MHz
Nominal 50 ohm impedance
Voltage Standing Wave Ration (VSWR) less than 2.5.1
3. There are 3 methods to provide power to the router:
A. 4-pin Molex connector - available on SN6x00
B. 4-pin screw terminal - available on Sn-6xx1/EB
C. Side mounted 2.5mm barrel connector - all models
D. Power-over-Ethernet - available on SN-6x01EB
The modem required a power source between 8 and 30 VDC to
operate:
5. Please allow 2-4 minutes for the unit to recognize the cellular data
card and connect to the cellular network. When this has occurred,
the signal strength LEDs should light up (see table on back). If sig-
nal strength is not lit or flashes slowly, please refer to the User
Manual at www. redlion.net.
6. Connect to the Ethernet RJ45 port for network connectivity.
ACCESSING THE WEB USER INTERFACE
1. Connect PC to IndustrialPro Router
Connect a CAT-5 Ethernet cable between the local PC and the unit’s
Ethernet port. Verify that the link LED is lit
2. Setup PC IP Address.
PC to Ethernet Interfaces
Select “Use the following IP address” and fill in the blank fields
with the information below
:
3. Access Web User Interface
Open a web browser and enter the following in the address bar:
http://192.168.0.1:10000
LOGIN INSTRUCTIONS
User Name: admin (lowercase letters)
Password: last six digits of the unit’s serial number
Upon successfully logging in, the web UI will launch.
Note: For security purposes, it is recommended that the admin pass-
word be changed according to your internal policies.
To change password, go to: Admin->Access Settings.
Web UI:
You are now connected to the web interface. If you should see anything
other than the screen shown above, please refer to the RAM-6021 User
Manual, located on our website: www.redlion.net.
LABEL COLOR DESCRIPTION
GND Black Ground
PWR+ Red Power 8 to 30 VDC
IN White Digital and analog input
OUT Green Digital output
For assistance with configuring your PC, see the appropri-
ate Microsoft support webpage listed at:
http://support.microsoft.com
Ethernet 0
IP Address 192.168.0.2
Subnet Mask 255.255.255.0
Default Gateway 192.168.0.1
Preferred DNS 192.168.0.1