1. Overview
The NPort 6250 series of secure serial device servers provide
reliable serial-to-Ethernet connectivity for a wide range of serial
devices. The NPort 6250 supports TCP Server, TCP Client, UDP,
and Pair-Connection operation modes to ensure the compatibility
of network software. In addition, the NPort 6250 also supports
Secure TCP Server, Secure TCP Client, Secure Pair-Connection,
and Secure Real COM modes for security critical applications such
as banking, telecom, access control and remote site management.
2. Package Checklist
Before Installing NPort 6250 secure device server, verify that the
package contains the following items:
1 NPort 6250
Document & Software CD
Quick Installation Guide (this guide)
Power Adaptor
Product Warranty Statement
2 wall mount ears
Optional Accessories
DK-35A: DIN-Rail Mounting Kit (35 mm)
DIN-Rail Power Supply
CBL-RJ45M9-150: 8-pin RJ45 to male DB9 cable
CBL-RJ45M25-150: 8-pin RJ45 to male DB25 cable
NOTE
Please notify your sales representative if any of the above
items are missing or damaged.
3. Hardware Introduction
The NPort 6250 series has 3 models. A brief description of each
model is given below:
NPort 6250
Two RS-232/422/485 serial ports and one 10/100Tx Ethernet
port
NPort 6250-S-SC
Two RS-232/422/485 serial ports and one 100Fx single mode
fiber Ethernet port
NPort 6250-M-SC
Two RS-232/422/485 ports and one 100Fx multi mode fiber
Ethernet port
Reset ButtonPress the Reset button continuously for 5 sec to
load factory defaults: Use a pointed object, such as a straightened
paper clip or toothpick, to press the reset button. This will cause
the Ready LED to blink on and off. The factory defaults will be
loaded once the Ready LED stops blinking (after about 5 seconds).
At this point, you should release the reset button.
LED Indicators
LED Name
LED Color
LED Function
PWR
Red
Power is being supplied to the power
input.
Ready
Red
Power is on and the NPort 6250
is booting up.
Indicates an IP conflict, or, the
DHCP or BOOTP server did not
respond properly or a relay
output occurred. Check the
relay output first. If after
resolving the relay output the
RDY LED is still blinking, then
there is an IP conflict, or the
DHCP or BOOTP server did not
respond properly.
Green
Steady
on:
Power is on and the NPort 6250
is functioning normally.
Blinking:
The device server has been
located by the Administrator’s
Location function.
Off Power is off, or power error condition
exists.
Link
Orange
10 Mbps Ethernet connection.
Green
100 Mbps Ethernet connection.
Off
Ethernet cable is disconnected, or has a
short.
P1-P2
Orange
Serial port is receiving data.
Green
Serial port is transmitting data.
Off
No data is being transmitted or received
through the serial port.
P1-P2
in-use LEDs
Green
Serial port was opened by server side
software
Off
Serial port has not been opened by
server side software
Adjustable pull high/low resistor for RS-422/485
(150 K( or 1 K()
Jumpers are used to set the pull
high/low resistors. The default is
150 KΩ. Short the jumpers to set
this value to 1 KΩ. Do not use the
KΩ setting with RS
-232 mode,
since doing so will degrade the
RS
-232 signals and shorten the
communication distance.
4. Hardware Installation Procedure
STEP 1: Connect the 12-48 VDC power adaptor to the NPort 6250
and then plug the power adaptor into a DC outlet.
STEP 2: For first-time configuration, use a cross-over Ethernet
cable to connect the NPort 6250 directly to your computer’s
Ethernet cable. For connecting to a network, use a standard
straight-through Ethernet cable to connect to a hub or switch.
STEP 3: Connect the NPort 6250’s serial port(s) to serial
device(s).