HITEC 44253 Instructional manual - Page 1
1
HITEC 44253 Instructional manual - Page 2
2
INSTRUCTIONAL MANUAL
MULTI-CHEMISTRY CHARGER
PART NO. 44253
INTRODUCTION
SAFETY NOTES SET CONTENTS
SPECIFICATIONS
TROUBLESHOOTING
WARNINGS
Congratulations for purchasing the Hitec X1 Nano battery charger.
Our easy-to-operate 50-watt AC charger is the economical and ecient choice
for those of you on the go. Capable of charging the most popular battery
chemistries, including the latest LiPo High Voltage cell packs, the X1 Nano is
your mini friend with maximum power.
Please read this entire operating manual before using the X1 Nano
Charger. If you are unsure of its proper operation after reading the manual,
please seek advice from an experienced hobbyist or someone familiar with
proper battery charging procedures.
Hitec RCD USA will not be held responsible for any damages or injuries that may occur by
persons who fail to follow these warnings or who fail to properly follow the instructions
in this manual.
THE CHARGING AND DISCHARGING OF RC HOBBY BATTERIES CAN BE
DANGEROUS. FAILURE TO FOLLOW THESE EXPLICIT WARNINGS CAN
RESULT IN PROPERTY DAMAGE AND/OR LOSS OF LIFE.
A NEVER LEAVE YOUR CHARGER UNATTENDED WHILE IN OPERATION.
A NEVER CHARGE ON OR AROUND COMBUSTIBLE MATERIALS.
A NEVER CHARGE A DAMAGED BATTERY PACK.
A LOW COST, NO-NAME BATTERY PACKS POSE THE MOST DANGER. WE
RECOMMEND YOU ONLY USE BATTERY PACKS THAT ARE SOLD AND
WARRANTIED BY A REPUTABLE COMPANY.
A IT IS HIGHLY RECOMMENDED THAT YOU UTILIZE A SAFETY DEVICE SUCH
AS A STEEL CASE OR LIPO SACK™ WHILE CHARGING LITHIUM CHEMISTRY
BATTERIES.
A IT IS HIGHLY RECOMMENDED THAT YOU KEEP AN OPERABLE “CLASS A FIRE
EXTINGUISHER IN THE CHARGING AREA.
FAILURE TO FOLLOW THESE WARNINGS CAN BE CONSIDERED
NEGLIGENCE BY THE OPERATOR AND MAY NEGATE ANY CLAIMS
FOR DAMAGES INCURRED.
Warning
Warning
These warnings and safety notes are of the utmost importance. You
must follow these instructions for maximum safety. Failure to do so can damage
the charger and the battery and in the worst cases, may cause a re.
A The allowable AC input voltage is 100 -240V AC.
A Keep the charger away from dust, damp, rain, heat, direct sunlight and
excessive vibration.
A If the charger is dropped or suers any type of impact, it should be inspected
by an authorized service station before using it again.
A Make sure you know the specications of the battery to be charged or
discharged to ensure it meets the requirements of this charger. If the
program is set up incorrectly, the battery and charger can be damaged.
Never place a charger on a car seat, carpet or similar surface. Keep all
ammable volatile materials away from the operating area.
A Fire or explosion can occur due to overcharging.
A To avoid a short circuit between the charge lead, always connect the charge
cable to the charger rst, then connect the battery. Reverse the sequence
when disconnecting.
NEVER ATTEMPT TO CHARGE OR DISCHARGE THE FOLLOWING TYPES
OF BATTERIES:
A A BATTERY FITTED WITH AN INTEGRAL CHARGE CIRCUIT OR PROTECTION CIRCUIT.
A A BATTERY PACK WHICH CONSISTS OF DIFFERENT TYPES OF CELLS (INCLUDING
DIFFERENT MANUFACTURERS’ CELLS).
A A BATTERY THAT IS ALREADY FULLY CHARGED OR JUST SLIGHTLY DISCHARGED.
A NON-RECHARGEABLE BATTERIES (THESE POSE AN EXPLOSION HAZARD).
A A FAULTY OR DAMAGED BATTERY
A BATTERIES INSTALLED IN A DEVICE OR WHICH ARE ELECTRICALLY LINKED TO OTHER
COMPONENTS
A BATTERIES THAT ARE NOT EXPRESSLY STATED BY THE MANUFACTURER TO BE
SUITABLE FOR THE CURRENTS THE CHARGER DELIVERS DURING THE CHARGE
PROCESS
1.) HITEC X1 NANO CHARGER 2.) AC POWER CORD 3.) XT60 CHARGE CABLE
X1 Nano Specications
AC Input
Battery Type / Cell Count
Charge Circuit Power
Selectable Charge Currents
Current Drain for LiPo Balancing
Connection break
or wrong connection
Polarity (+ and -) connections
of battery are incorrect
Dead cell or imbalance
between cells is too high
Over current protection
Check the connection between the charger
and the battery.
Make sure the charge lead is connected properly
to the charger to ensure it is wired correctly
Decrease charge rate to safe level for the battery
pack, or dispose of shorted battery
Safely dispose of damaged battery
Once the error condition has been resolved, press “BATT TYPE” button to reset the charger. If the error
can not be solved, please disconnect the power cord from the wall socket and unplug the battery from
the charger.
Cell Termination Voltage
100 - 240 Volts AC
LiPo,LiFe and LiHV / 2 4S NiMH:6 - 8S
50 Watts
1, 2 , 3 or 4 Amps 10%
300 mA per cell
LiPo: 4.2 0.02 / LiFe: 3.6V 0.02V
LiHV: 4.35 0.02 / NiMH: -∆V
Net Weight 6.6 oz (188 g)
Dimensions
If there is an error, all four status LED of the charge will blinking
2.7 x 4.3 x 1.6 in
(69.4 x 110.7 x 40.5 mm)
.
1
2
3
4
.
LED Blinking Times Problem
Solution