Leviton decora smart DZ1KD Installation Instructions And Operators Manual

Download Installation instructions and operators manual of Leviton decora smart DZ1KD Dimmer for Free or View it Online on All-Guides.com.

Brand: Leviton

Category: Dimmer

Type: Installation instructions and operators manual for Leviton decora smart DZ1KD

Pages: 3

Download Leviton decora smart DZ1KD Installation instructions and operators manual

Leviton decora smart DZ1KD Installation instructions and operators manual - Page 1
1
Leviton decora smart DZ1KD Installation instructions and operators manual - Page 2
2
Leviton decora smart DZ1KD Installation instructions and operators manual - Page 3
3
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that
this product at the time of its sale by Leviton is free of defects in materials and workmanship under
normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct
such defects by repair or replacement, at its option. For details visit www.leviton.com or call
1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal of
this product or reinstallation. This warranty is void if this product is installed improperly or in an
improper environment, overloaded, misused, opened, abused, or altered in any manner, or is
not used under normal operating conditions or not in accordance with any labels or instructions.
There are no other or implied warranties of any kind, including merchantability and fitness
for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the
duration of any such implied warranty, including merchantability and fitness for a particular purpose,
is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential
damages, including without limitation, damage to, or loss of use of, any equipment, lost
sales or profits or delay or failure to perform this warranty obligation. The remedies provided
herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise
.
DI-000-DZ1KD-02A-X4
DI-000-DZ1KD-02A-X4
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in
writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality Assurance
Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at
1-800-405-5320.
© 2016 Leviton Mfg. Co., Inc.
© 2016 Leviton Mfg. Co., Inc.
COPYRIGHT AND TRADEMARK INFORMATION
Decora is a registered trademark of of Leviton Manufacturing Co., Inc.
Z-Wave and Z-Wave Plus are registered trademarks of Sigma Designs and its subsidiaries in the
United States and other countries. Use herein of third party trademarks, service marks, trade names,
brand names and/or product names are for informational purposes only, are/may be the trademarks
of their respective owners; such use is not meant to imply affiliation, sponsorship, or endorsement.
No part of this document may be reproduced, transmitted or transcribed without the express
written permission of Leviton Manufacturing Co., Inc.
PATENTS
This product is covered by U.S. Patent No. 8,664,886 and corresponding foreign patents.
TECHNICAL SUPPORT
For additional information contact Leviton’s Technical Support at:
1-800-824-3005 or visit Leviton’s website at www.leviton.com
INSTALLATION INSTRUCTIONS
Dimmer with Z-Wave
®
Technology
Cat. No. DZ1KD
Universal Incandescent, LED, CFL, Magnetic Low
Voltage, or Fluorescent Dimmer
Rated: 120 VAC, 60 Hz
1000W Incandescent
1000VA Mark 10
®
Fluorescent
450W LED/CFL
Schedule or
dim lights from
anywhere using
a compatible
Z-Wave
®
controller
DIM/BRIGHT Bar
BRIGHTEN:
Tap the TOP half of the DIM/BRIGHT Bar – Lights will jump to the
next brightness setting. Hold the TOP half of the DIM/BRIGHT Bar –
Lights will brighten.
DIM:
Tap the BOTTOM half of the DIM/BRIGHT Bar – Lights will jump to
the next dim setting. Hold the BOTTOM half of the DIM/BRIGHT Bar
– Lights will dim.
NOTE: When lights are OFF you can change the light level that the
lights will turn ON to using the DIM/BRIGHT Bar. If there is a power
outage, when the power is restored, the lights will return to the last
setting before the power interruption.
NOTE: At default the locator light will
illuminate when the load is in the OFF
position to facilitate access in the dark.
NOTE: If using the dimmer in a 3-way
application, the lights will turn ON at
brightness set on dimmer’s DIM/BRIGHT
bar. The lighting can be controlled from
either the dimmer, the remote location or a
Z-Wave
®
enabled controller.
Rocker (Default settings)
Turn ON from OFF position:
Tap TOP of Rocker: Lights turn ON to
preset level.
Turn OFF from ON position:
Tap BOTTOM of Rocker. Lights turn OFF.
OPERATION
LED Brightness
Display
DIM/BRIGHT
Bar
Rocker
Locator
LED
Cleaning: Clean with a damp cloth.
DO NOT use chemical cleaners.
On the dimmer only, engage the air-gap switch
by gently pulling out from the bottom of the
DIM/BRIGHT Bar until the bottom of the bar
lifts completely out of the frame and a click is
heard (refer to Figure). LED's will turn OFF.
This will stop power to the fixture to replace
the bulb. After servicing is complete, press the
DIM/BRIGHT Bar back into place for normal
operation.
Restore power at circuit breaker or fuse.
Press pad until locator light is OFF.
Lights should turn ON. If lights do not
turn ON, press the TOP half of the DIM/
BRIGHT Bar until the lights brighten.
If lights still do not turn ON, refer to
the TROUBLESHOOTING section.
Testing your Dimmer prior to mounting in
wall box:
Step 5
Position all wires to provide room
in outlet wall box for device.
Ensure that the word "TOP" is
facing up on device strap.
Partially screw in mounting screws
in wall box mounting holes.
NOTE: Dress wires with a bend as
shown in diagram in order to relieve
stress when
mounting
device.
NOTE: If using in a dimmable fluorescent or CFL application see
Load Type Setup prior to testing the device.
Dimmer Mounting:
TURN OFF POWER AT
CIRCUIT BREAKER OR FUSE.
Step 6
Restore Power:
Restore power at circuit breaker or fuse.
Installation is complete.
Step 7
Installation may now be completed by
tightening mounting screws into wall box.
Attach wall plate.
AIR GAP
INCLUSION TO A Z-WAVE
®
NETWORK
Leviton Decora Smart
TM
Z-Wave
®
devices support two
methods of inclusion. When using a Z-Wave Plus
TM
certified
controller choose Network Wide Inclusion.
Network Wide Inclusion:
Network Wide Inclusion allows your device to be included into
the network using devices already in the network to assist with
communication. Work your way from the closest devices to the
controller outward.
Enter Programming Mode by holding the top of the paddle for 7
seconds, the Locator LED will blink amber.
Tap the top of the paddle one time.
The Locator LED will quickly flash green.
The Decora Smart
TM
Z-Wave
®
device is ready to learn into the Z-Wave
®
network.
Follow directions in the Z-Wave
®
controller to complete the
adding process.
Upon successful addition to network the LED will turn off and
then blink green 3 times.
If the adding process is not successful the LED will flash red 3 times.
Traditional Inclusion:
For older controllers Traditional Inclusion is supported.
Depending on the age of the controller the controller will need
to be 3 to 35 feet from the device when including.
Enter Programming Mode by holding the top of the paddle for 7
seconds, the Locator LED will blink amber.
The Decora Smart
TM
Z-Wave
®
device is ready to add to the Z-Wave
®
network.
Follow directions in the Z-Wave
®
controller to enter learn mode.
Tap the top of the paddle one time. The Locator LED will quickly
flash green. The Z-Wave
®
controller will begin to pair with the
Decora Smart
TM
device.
Upon successful addition to the network the LED will turn off
and then blink green 3 times.
If the adding process is not successful the LED will flash red 3 times.
FACTORY DEFAULT
LOAD TYPE SETUP
Leviton Decora Smart
TM
Z-Wave
®
dimmers are compatible with
different types of loads. Choosing the correct load type will
increase compatibility and provide proper operation.
Incandescent Loads (Default):
Enter Programming Mode by holding the top of the paddle for 7
seconds
, the Locator LED will blink amber.
Tap the top of the paddle 4 times.
The Locator LED will quickly flash green and amber.
Tap the top of the paddle 4 times.
The Locator LED will flash green/amber 3 times to confirm the
selection.
LED Loads:
Enter Programming Mode by holding the top of the paddle for 7
seconds
, the Locator LED will blink amber.
Tap the top of the paddle 4 times.
The Locator LED will quickly flash green and amber.
Tap the top of the paddle 5 times.
The Locator LED will flash green/red 3 times to confirm the
selection.
CFL Loads:
Enter Programming Mode by holding the top of the paddle for 7
seconds
, the Locator LED will blink amber.
Tap the top of the paddle 4 times.
The Locator LED will quickly flash green and amber.
Tap the top of the paddle 6 times.
The Locator LED will flash red/amber 3 times to confirm the
selection.
Mark 10
®
Loads:
Enter Programming Mode by holding the top of the paddle for 7
seconds
, the Locator LED will blink amber.
Tap the top of the paddle 4 times.
The Locator LED will quickly flash green and amber.
Tap the top of the paddle 7 times.
The Locator LED will flash red/amber/green 3 times to confirm
the selection.
LOCATOR LED SETUP
Leviton Decora Smart
TM
Z-Wave
®
devices have a locator LED on the
bottom of the paddle. The operation of the LED can be changed.
Status Mode: LED On when the load is On:
The Locator LED is used to show the current state of the load:
Enter Programming Mode by holding the top of the paddle for 7
seconds, the Locator LED will turn amber.
Tap the top of the paddle 4 times.
The Locator LED will quickly flash green and amber.
Tap the top of the paddle once.
The Locator LED will flash green 3 times to confirm the selection.
Locator Mode: LED On when the load is Off (Default):
The Locator LED is designed to easily find the dimmer in a dark room.
If the setting has been changes and you wish to return to the default
operation.
Enter Programming Mode by holding the top of the paddle for 7
seconds, the Locator LED will turn amber.
Tap the top of the paddle 4 times.
The Locator LED will quickly flash green and amber.
Tap the top of the paddle twice.
The Locator LED will flash amber 3 times to confirm the selection.
LED Off: Locator LED is always Off:
The Locator LED is turned off:
Enter Programming Mode by holding the top of the paddle for 7
seconds, the Locator LED will blink amber.
Tap the top of the paddle 4 times.
The Locator LED will quickly flash green and amber.
Tap the top of the paddle 3 times.
The Locator LED will flash red 3 times to confirm the selection.
EXCLUSION FROM A Z-WAVE
®
NETWORK
When removing a device from a Z-Wave
®
network best
practice is to use the exclusion command found in the
Z-Wave
®
controller.
Enter Programming Mode by holding the top of the paddle for 7
seconds, the Locator LED will blink amber.
Follow directions in the Z-Wave
®
controller to enter exclusion
mode
Tap the top of the paddle one time. The Locator LED will quickly
flash green.
The Z-Wave
®
controller will exclude the Decora Smart
TM
device
The Z-Wave
®
controller will confirm successful exclusion from
the network.
Devices are programmed to automatically time-out of any settings after 20
seconds.
EXITING PROGRAMMING
Leviton Decora Smart
TM
Devices are configurable
through the paddle as well as over the Z-Wave
®
network.
Compatible Z-Wave
®
controllers can add support for
additional advanced options. Consult your Z-Wave
®
controller manufacturer for compatibility with advanced
feature support.
Fade On Time
Parameter No: 1, Length: 1 Byte
Valid Values = 0 to 253 (default 2)
- 0 = Instant On
- 1 - 127 = Seconds: 1 - 127 seconds
- 128 - 253 (0x80 - 0xFD) = Minutes: 1 - 126 minutes
Fade Off Time
Parameter No: 2, Length: 1 Byte
Valid Values = 0 to 253 (default 2)
- 0 = Instant Off
- 1 - 127 = Seconds: 1 - 127 seconds
- 128 - 253 (0x80 - 0xFD) = Minutes: 1 - 126 minutes
Minimum Light Level
Parameter No: 3, Length: 1 Byte
Valid Values = 0 to 100 (default 10)
Maximum Light Level
Parameter No: 4, Length: 1 Byte
Valid Values = 0 to 100 (default 100)
Preset Light Level
Parameter No: 5, Length: 1 Byte
Valid Values = 0 to 100 (default 0)
- 0 = Memory Dim - Last dim state
- 1 - 100 = Level
LED Dim Level Indicator Timeout
Parameter No: 6, Length: 1 Byte
Valid Values = 0 to 255 (default 3)
- 0 = Level Indicators Off
- 1 - 254 (0x01 - 0xFE) = Level Indicator Timeout
(seconds)
- 255 (0xFF) = Levels Always On
Locator LED Status
Parameter No: 7, Length: 1 Byte
Valid Values = 0 to 255 (default 255)
- 0 = LED Off
- 254 (0xFE) = Status Mode
- 255 (0xFF) = Locator Mode
Load Type
Parameter No: 8, Length: 1 Byte
Valid Values = 0 to 3 (default 0)
- 0 = Incandescent
- 1 = LED
- 2 = CFL
- 3 = Mark 10
ADVANCED OPTIONS
When removing a device from a network it is best practice to use the
Exclusion process. In situations where a device needs to be returned
to factory default follow the following steps. A reset should only be used
when a controller is inoperable or missing.
Hold the the top of the paddle for a total of 14 seconds.
After the first 7 seconds the LED turns amber.
The Locator LED will quickly flash red/amber after 14 seconds.
Release the the top of the paddle and the device will reset.
MINIMUM / MAXIMUM DIM LEVELS
Leviton Decora Smart
TM
Z-Wave
®
devices have the ability to alter the
minimum dim level to increase compatibility with LED bulbs as well
as alter the maximum brightness to save energy.
To change minimum dim level:
Enter Programming Mode by holding the top of the paddle for 7
seconds, the Locator LED will turn amber.
Tap the top of the paddle 5 times.
The Locator LED will quickly flash red and amber.
Tap the top of the paddle once.
The Locator LED will flash amber.
Use the dim/bright bar to adjust the minimum dim level.
Hold the top of the paddle to save.
To change maximum dim level:
Enter Programming Mode by holding the top of the paddle for 7
seconds, the Locator LED will turn amber.
Tap the top of the paddle 5 times.
The Locator LED will quickly flash red and amber.
Tap the top of the paddle 2 times.
The Locator LED will flash red.
Use the dim/bright bar to adjust the maximum dim level.
Hold the top of the paddle to save.
Z-WAVE
®
ASSOCIATIONS
Group Number: 1
Maximum Nodes: 5
Z-Wave Plus
TM
Lifeline: A NOTIFICATION frame is sent to
the nodes
in this association group when a Lifeline event occurs.
All nodes in the association group receive notification of
status changes.
Z-WAVE PLUS INFO
ASSOCIATION
ASSOCIATION GRP INFO
VERSION
MANUFACTURER SPECIFIC
CONFIGURATION
DEVICE RESET LOCALLY
POWERLEVEL
SWITCH MULTILEVEL
BASIC
SWITCH ALL
SCENE ACTUATOR CONF
SCENE ACTIVATION
FIRMWARE UPDATE MD V2
HAIL
ADDITIONAL SUPPORTED CLASSES
Gently pull out from
bottom
decora smart™
Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly with wire connectors of dimmer or
terminal screws of remote.
- If using in a dimmable fluorescent application see Load Type
Setup prior to testing the device.
Light does not turn ON and Locator LED does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Neutral not wired to Dimmer (White wire).
- Confirm that the device is being supplied from a 120V AC, 60 Hz
source ONLY.
Intermittent dimmer operation
- Confirm that the Load being controlled does not exceed the
1000VA dimmer limit.
Remote does not operate lights
- Ensure that total wire length does not exceed 300 ft.
- Ensure wiring is correct.
TROUBLESHOOTING