Download Quick installation manual of Comtrol Rocket linx ES8505-XT Switch for Free or View it Online on All-Guides.com. This version of Comtrol Rocket linx ES8505-XT Manual compatible with such list of devices, as: Rocket linx ES8505-XT, Rocket linx ES8508, Rocket linx ES8508F, Rocket linx ES8508F-XT

Comtrol Rocket linx ES8505-XT Quick installation manual - Page 1
1
Comtrol Rocket linx ES8505-XT Quick installation manual - Page 2
2
Comtrol Rocket linx ES8505-XT Quick installation manual - Page 3
3
Comtrol Rocket linx ES8505-XT Quick installation manual - Page 4
4
Comtrol Rocket linx ES8505-XT Quick installation manual - Page 5
5
Comtrol Rocket linx ES8505-XT Quick installation manual - Page 6
6
Comtrol Rocket linx ES8505-XT Quick installation manual - Page 7
7
Comtrol Rocket linx ES8505-XT Quick installation manual - Page 8
8
QUICK INSTALLATION GUIDE
2000577 Rev B | Release Date - September, 2013
ROCKETLINX
ES8508
ES8508 | ES8508F | ES8508-XT | ES8508F-XT
In-band management means that you connect remotely using the ES8508
IP address through the network. You can remotely connect with the
ES8508 Java applet web interface or a Telnet console and the CLI.
The following procedure uses a web browser to congure ES8508 features.
Refer to the
RocketLinx ES8508 Series User Guide
for other conguration
methods.
1. If necessary, install the latest version of the Java Runtime
Environment, which is required to run the web management interface.
2. Open a web browser and enter the IP address of the ES8508.
3. Click Run when Java prompts you to run the applet.
4. Enter admin for both the user name and the password when
prompted.
5. Use the web interface to congure your device as needed for your
network.
You can use the help system or the
RocketLinx ES8508 Series User Guide
for information about conguring RocketLinx ES8508 features.
COMTROL CUSTOMER SERVICE
You can use one of the following methods to contact Comtrol.
Contact Method Web Address or Phone Number
Support http://www.comtrol.com/support
Downloads ftp://ftp.comtrol.com/html/ES8508_main.htm
Website http://www.comtrol.com
Phone +1 763.957.6000
9. Optionally, select the appropriate Network Topology, which is an
informational eld.
10. Click the Apply Changes button.
11. Click Close to return to the main screen.
12. You are now ready to congure the ES8508 features.
LED INDICATORS
You can also view the LEDs for the ES8508 through the web interface
using the
Device Front Panel
page.
LED Name LED On LED Blinking LED Off
SYS Green: System ready Green: Firmware
loading
Power off
PWR1/2 Green: System power
ready
Not applicable System not ready
R.S. (Ring
Status)
Green: Ring is normal
Amber: Abnormal ring
Green: Ring with the
wrong port
Amber: The devices
ring port failed
Switch working in slave
mode
DO1 Relay is active and
contacts have been
shorted
Not applicable DO not activated
DI1 High digital signal is
detected
Not applicable DI not activated
LNK/ACT Port is linked Port active Port link down or port
not connected
FEATURE CONFIGURATION
The ES8508 provides both in-band and out-band conguration methods:
Out-band management means that you congure the ES8508 using the
RS-232 console cable and the Command Line Interface (CLI) to access the
ES8508 without attaching an admin PC to the network. You can also use
out-bound management, if you lost the network connection to the ES8508.
PROGRAMMING THE IP ADDRESS
Congure the IP address using one of the following methods:
PortVision DX (available on the RocketLinx CD shipped with the
product)
Web browser
Telnet
Command line interface (CLI) using the RS-232 console cable
The easiest way to congure a static IP address for your network in
the ES8508 is to use a Windows host and PortVision DX (see below).
For information about using other conguration methods, refer to the
RocketLinx ES8508 Series User Guide.
Note:
Optionally, you can use NetVision if you are accustomed to
using NetVision. PortVision DX is replacing NetVision. NetVision is not
documented in the RocketLinx ES8508 Series User Guide.
The following procedure uses PortVision DX to program network settings.
1. Install PortVision DX on a host system with a Windows operating
system. If you need assistance installing PortVision DX, see the
RocketLinx ES8508 Series User Guide.
2. Start PortVision DX. PortVision DX can be started from Start --> All
Programs --> Comtrol --> PortVision DX.
3. Click the Scan button.
4. Select the Comtrol product families that you want to locate and click
the Scan button.
5. Right-click the ES8508 in the Device List pane (lower) that you want to
congure and click Properties.
6. Enter a user-friendly Device Name.
7. Optionally, enter the ES8508 serial number, which displays a friendly
device name in the
Device List
pane on the main page.
8. Select DHCP IP or Static IP for the
IP Mode
.
If you select DHCP IP, go to Step 9.
If you select Static IP, enter an IP address, Subnet Mask, and
Default Gateway value for your network.