Carrier ERVXXSVB1100 Product Data
Download Product data of Carrier ERVXXLHB1200 Fan for Free or View it Online on All-Guides.com. This version of Carrier ERVXXLHB1200 Manual compatible with such list of devices, as: ERVXXSHB1100, ERVXXSVB1100, HRVXXLHB1150, HRVXXSHB1100, HRVXXSVB1100
Brand: Carrier
Category: Fan
Type: Product data
Model: Carrier ERVXXLHB1200 , Carrier ERVXXSHB1100 , Carrier ERVXXSVB1100 , Carrier HRVXXLHB1150 , Carrier HRVXXLHB1250 , Carrier HRVXXLVU1330 , Carrier HRVXXSHB1100 , Carrier HRVXXSVB1100 , Carrier HRVXXSVU1157
Pages: 14 (1.68 Mb)
HRVXX
Heat Recovery Ventilators
ERVX X
Energy Recovery Ventilators
Product Data
A05229
ERVXXSVB1100, HRVXXSVB1100
A05330
ERVXXSHB1100, HRVXXSHB1100
A10299
ERVXXLHB1200, HRVXXLHB1150, HRVXXLHB1250
A12338
HRVXXSVU11 57
A12339
HRVXXLVU1330
The Heat Recovery Ventilation (HRV) and Energy Recovery
Ventilator (ERV) systems offered by Carrier are the finest on the
market today. These units provide efficient and cost effective heat
recovery during the heating season when needed most.
As temperatures drop below 23_F(--5_C), indoor air is recirculated
periodically through the heat exchanger core to prevent frost from
forming. Competitors’ methods of supplementary electric defrost
waste energy. Unlike rotary wheel heat exchangers which mix air
streams, these cross--flow or counterflow heat exchangers ensure
that there is no mixing of the stale air stream with the fresh outdoor
air stream.
A filter installed on the incoming outdoor air stream removes large
airborne particles from the intake air stream before they enter the
heat exchanger and reduces the maintenance required. The units’
acoustically engineered design make Carrier ventilators the quietest
on the market and ensures that comfort is felt, not heard.
Unlatching two (2) suitcase style latches allows easy removal of the
filters and core for cleaning on most units.
NOTE: The unit should not be installed in an attic or
unconditioned space unless provisions are made for drain line
freezing and condensation.
STANDARD FEATURES
HRV
S Energy saving defrost cycle
S Cross-- flow, counterflow heat exchangers
S One filter on incoming air; one filter on outgoing air to
protect core
S Acoustical design
S Polypropylene heat exchanger core
ERV
S Integrated airflow balancing points
S Integrated furnace interlock
S High pressure blowers
S Onboard control for continuous high/low ventilator operation
S Energy saving defrost cycle
S Cross-- flow, counterflow heat exchangers
S One filter on incoming air; one filter on outgoing air to
protect core
S No--tools maintenance
S Enthalpic heat exchanger core