LEGRAND DT-300 Installation Instructions Manual

Download Installation instructions manual of LEGRAND DT-300 Kitchen Appliances for Free or View it Online on All-Guides.com.

Brand: LEGRAND

Category: Kitchen Appliances

Type: Installation instructions manual for LEGRAND DT-300

Pages: 21

Download LEGRAND DT-300 Installation instructions manual

LEGRAND DT-300 Installation instructions manual - Page 1
1
LEGRAND DT-300 Installation instructions manual - Page 2
2
LEGRAND DT-300 Installation instructions manual - Page 3
3
LEGRAND DT-300 Installation instructions manual - Page 4
4
LEGRAND DT-300 Installation instructions manual - Page 5
5
LEGRAND DT-300 Installation instructions manual - Page 6
6
LEGRAND DT-300 Installation instructions manual - Page 7
7
LEGRAND DT-300 Installation instructions manual - Page 8
8
LEGRAND DT-300 Installation instructions manual - Page 9
9
LEGRAND DT-300 Installation instructions manual - Page 10
10
LEGRAND DT-300 Installation instructions manual - Page 11
11
LEGRAND DT-300 Installation instructions manual - Page 12
12
LEGRAND DT-300 Installation instructions manual - Page 13
13
LEGRAND DT-300 Installation instructions manual - Page 14
14
LEGRAND DT-300 Installation instructions manual - Page 15
15
LEGRAND DT-300 Installation instructions manual - Page 16
16
LEGRAND DT-300 Installation instructions manual - Page 17
17
LEGRAND DT-300 Installation instructions manual - Page 18
18
LEGRAND DT-300 Installation instructions manual - Page 19
19
LEGRAND DT-300 Installation instructions manual - Page 20
20
LEGRAND DT-300 Installation instructions manual - Page 21
21
Wattstopper
®
360° Dual Technology • Low Voltage Occupancy Sensor (version 3)
with Light Level, Isolated Relay, and Manual On feature
Double technologie à 360° • Détecteur de présence basse tension (v3)
avec les fonctionnalités de niveau de luminosité, de relais isolé, et de
marche manuelle
Doble tecnología de 360° • Sensor de presencia de bajo voltaje (v3)
con nivel de luz, relé aislado, y función de encendido manua
Installation Instructions • Instructions d’Installation • Instrucciones de Instalación
No: 23947 – 12/16 rev. 2
Catalog Number • Numéro de Catalogue • Número de Catálogo: DT-300
Country of Origin: Made in China • Pays d’origine: Fabriqué en Chine • País de origen: Hecho en China
DT-300-U is BAA and TAA compliant (Product produced in the U.S.)
SPECIFICATIONS
Voltage 18-28VDC/VAC, half wave rectified AC
Current Consumption .............................................28mA DC/81mA AC
Power Supply .............................................. WattStopper Power Packs
Isolated Relay Rating ............................................... 1A @30VDC/VAC
Operating Temperature .................................32° to 131°F (0° to 55°C)
Light Level One-Step Adjustment ................................... 10FC—300FC
Time Delay Adjustment ................................30 seconds to 30 minutes
Walk-Through Mode ....................... 3 minutes if no activity after 30 sec
Test Mode ................................................ 5 sec. upon DIP switch reset
PIR Coverage (Typical) ............................................................1300 ft2
Sensitivity Adjustment ................ High or Low (DIP switch setting)
Ultrasonic Coverage (Typical) .................................................. 1300 ft2
Sensitivity Adjustment .............................Min. to Max. (trimpot)
Frequency .......................................................................40kHz
UL & CUL Listed for use with WattStopper Power Packs
UNIT DESCRIPTION
The WattStopper DT-300 360° Dual Technology occupancy sensors combine advanced passive infrared (PIR) and ultrasonic technologies
into one unit. The combination of these technologies helps to eliminate false triggering problems even in difficult applications.
The DT-300 turns lighting systems on and off based on occupancy. The DT-300 provides numerous operating modes that can be combined to
create the ideal custom control. The sensors can be configured to turn lighting on and hold it on as long as either or both technologies detect
occupancy. After no movement is detected for a user specified time (30 seconds to 30 minutes), the lights are switched off. A “walk-through”
mode can turn lights off after only 3 minutes if no activity is detected after 30 seconds of an occupancy detection.
The DT-300 operates on 24V supplied by WattStopper Power Packs. DT-300 sensors also have an isolated relay with Normally Open and
Normally Closed contacts for interfacing with HVAC or EMS.
COVERAGE PATTERN
The DT-300 provides a 360° coverage pattern. The coverage shown represents walking motion at a mounting height of 8-12 feet. For
building spaces with lower levels of activity or with obstacles and barriers, coverage size may decrease. The coverage for PIR ONLY
trigger mode varies with mount height. Refer to pattern below for details. Ultrasonic coverage is roughly the same for 8-12 foot mount
heights. Refer to PIR and Ultrasonic trigger mode coverage for details.
Side View
8ft
(2.4m)
10ft
(3.0m)
12ft
(3.7m)
40ft
(12.2m)
30ft
(9.1m)
40ft
(12.2m)
30ft
(9.1m)
20ft
(6.1m)
20ft
(6.1m)
10ft
(3.0m)
10ft
(3.0m)
0
0
PIR Only Coverage
Top View
8-12 foot Mounting Height
36 ft
(10.97m)
36 ft x 36 ft
(10.97m x 10.97m)
PIR
Coverage
Ultrasonic
Coverage