7. While firmly pushing the handle of the power supply with one hand, use the other
hand to pull the spring-loaded locking pin in the release lever away from the chassis
and turn the release lever in the clockwise direction until it stops.
8. Let go of the locking pin in the release lever. Ensure that it is seated in the corresponding
hole in the chassis.
NOTE: If you have a Juniper J-Care service contract, register any addition,
change, or upgrade of hardware components at
https://www.juniper.net/customers/support/tools/updateinstallbase/ . Failure
to do so can result in significant delays if you need replacement parts. This
note does not apply if you replace existing components with the same type
of component.
To connect power to an AC power supply, see “Connecting AC Power to an EX9214
Switch” on page 154.
Related
Documentation
Removing an AC Power Supply from an EX9214 Switch on page 191•
• AC Power Supply in an EX9214 Switch on page 45
• Power Requirements for EX9200 Switch Components on page 95
• Field-Replaceable Units in an EX9200 Switch on page 19
Removing an AC Power Supply from an EX9214 Switch
The AC power supply in an EX9214 switch is a hot-removable and hot-insertable
field-replaceable unit (FRU) installed in the rear panel.
CAUTION: Before you remove a power supply, ensure that you have power
supplies sufficient to powerthe switch that remains in the chassis.See “Power
Requirements for EX9200 Switch Components” on page 95.
CAUTION: Do not leave the power supply slot empty for a long time while
the switch is operational. Either replace the power supply unit promptly or
install a cover panel over the empty slot.
NOTE: After powering off a power supply, wait for at least 60 secondsbefore
turning it back on.
Before you remove an AC power supply from the switch: