IAI SCON-CA First Step Manual

Download First step manual of IAI SCON-CA Controller, Switch for Free or View it Online on All-Guides.com.

Brand: IAI

Category: Controller , Switch

Type: First step manual

Model: IAI SCON-CA , IAI SCON-CAL , IAI SCON-CGAL

Pages: 5

Download IAI SCON-CA First step manual

IAI SCON-CA First step manual - Page 1
1
IAI SCON-CA First step manual - Page 2
2
IAI SCON-CA First step manual - Page 3
3
IAI SCON-CA First step manual - Page 4
4
IAI SCON-CA First step manual - Page 5
5
SCON-CA/CAL/CGAL
First Step Guide Fifth Edition
Thank you for purchasing our product.
Make sure to read the Safety Guide and detailed Instruction Manual (DVD) included with the product in addition to
this First Step Guide to ensure correct use.
This Instruction Manual is original.
Using or copying all or part of this Instruction Manual without permission is prohibited.
The company names, names of products and trademarks of each company shown in the sentences are registered
trademarks.
EtherCAT® is a registered mark of Beckoff Automation GmbH.
EtherNet/IP is a trademark used under the license of ODVA.
Product Check
This product is comprised of the following parts if it is of standard configuration.
If you find any fault in the contained model or any missing parts, contact us or our distributor.
1. Parts
No. Part Name Model Reference
1 Controller Main Body
Refer to “How to read the model plate”, “How to read the
model of the controller”.
Accessories
2 System I/O Plug FMC1.5/4-ST-3.5
(Supplier : Phoenix Contact)
3 Power Supply Plug for Brake MC1.5/2-ST-3.5
(Supplier : Phoenix Contact)
Applicable Cable Size
0.5mm
2
(AWG20)
4 AC Power Supply plug MSTB2.5/6-STF-5.08
(Supplier : Phoenix Contact)
Applicable Cable Size
2.0mm
2
(AWG14)
5 Absolute Battery AB-5
Enclosed in Absolute Type
6 Dummy plug DP-5 Enclosed in SCON-CGAL
7 First Step Guide
8 Instruction Manual (DVD)
9 Safety Guide
2. Teaching Tool (to be purchased separately)
A teaching tool such as PC software is necessary when performing the setup for position setting, parameter setting, etc. that
can only be done on the teaching tool.
Please prepare either of the following teaching tools such as PC software.
No. Part Name Model
1
PC Software (RCS232C converter adapter
+
external equipment communication cable are included)
RCM-101-MW
2
PC Software (USB converter adapter
+
USB cable
+
external equipment communication cable are included)
RCM-101-USB
3 Touch Panel Teaching CON-PT
4 Touch Panel Teaching (Dead-man Switch is included) CON-PD
5 Touch Panel Teaching (Dead-man Switch + TP Adapter (RCB-LB-TG) are included) CON-PG
6 Touch Panel Teaching TB-01 TB-01
7 Touch Panel Teaching TB-01 (with dead-man switch attached on the left) TB-01D
8 Touch Panel Teaching TB-01 (with dead-man switch attached on the right) TB-01DR
3. Instruction Manuals Related to this Product, which are Contained in the Instruction Manual (DVD).
No. Name Manual No.
1 SCON-CA Controller Instruction Manual ME0243
2 EtherCAInstruction Manual ME0273
3 EtherNet/IP Instruction Manual ME0278
4 CC-Link (High Performance Type) Instruction Manual ME0254
5 DeviceNet (High Performance Type) Instruction Manual ME0256
6 PROFIBUS-DP (High Performance Type) Instruction Manual ME0258
7 CompoNet (High Performance Type) Instruction Manual ME0220
8 MECHATROLINK (High Performance Type) Instruction Manual ME0221
9 MECHATROLINKInstruction Manual ME0317
10 PROFINET-IO Instruction Manual ME0333
11 PC Software RCM-101-MW/ RCM-101-USB Instruction Manual ME0155
12 Touch Panel Teaching CON-PTA/PDA/PGA/PGAS Instruction Manual ME0295
13 Touch Panel Teaching TB-01 Position Controller Instruction Manual ME0324
4. How to Read the Model Plate
5. How to Read the Model of the Controller
Basic Specifications
List of Specifications
SCON-C/CA
Item
Less than 400W 400W or more
SCON-CAL/CGAL
Corresponding Motor Capacity 12W to 399W 400W to 750W 12W to 200W
Power-supply Voltage
Single-Phase 100 to 115V AC
Single-Phase 200 to 230V AC
(Power fluctuation within
±
10%)
Single-Phase 200 to 230V AC
(Power fluctuation within
±
10%)
Single-Phase 100 to 115V AC
Single-Phase 200 to 230V AC
(Power fluctuation within
±
10%)
Power-supply Voltage 100V AC
Rush
Current
*1
Power-supply Voltage 200V AC
20A (Controller side),
70A (Drive side)
20A (Controller side),
80A (Drive side)
30A (Controller side),
80A (Drive side)
Load Capacity Refer to Power Capacity and Heat Generation
Leak Current
*2
3.0mA Primary side when noise filter is connected to power supply line
Heat Generation Refer to Power Capacity and Heat Generation
Power Supply Frequency 50/60Hz
PIO Power Supply
*3
24V DC±10%
Power Supply for Electromagnetic Brake
(for actuator equipped with brake)
24V DC±10% 1A (MAX.)
(supplied from external equipment)
Transient Power Cutoff Durability 20ms (50Hz), 16ms (60Hz)
Motor Control System Sine Wave PWM Vector Current Control
Corresponding Encoder Incremental Serial Encoder, Absolute Serial Encoder,
ABZ (UVW) Parallel Encoder
Incremental Serial Encoder,
Absolute Serial Encoder,
Actuator Cable Length MAX. 20m
Serial Communication Interface RS485 : 1CH … based on Modbus Protocol RTU/ASCII
Speed : 9.6 to 230.4Kbps
Control available with serial communication in the modes other than the pulse train
PIO
Specifications
Signal I/O dedicated for 24V DC (selected from NPN/PNP) … Input 16 ports max.,
output 16 ports max.
External Interface
(Each dedicated
controller)
Fieldbus
Specification
EtherCAT, EtherNET/IP, PROFINET IO
PIO MAX. 10m
RS485 Total cable length 100m or less.
Cable Length
Fieldbus Refer to each Fieldbus specification
Data Setting and Input PC Software, Touch Panel Teaching, Teaching Pendant
Data Retention Memory Saves position data and parameters to non-volatile memory
(There is no limitation in number of writing)
Operation Mode Positioner Mode/Direct Mode
Number of Positions in Positioner
Mode
Standard 64 points, maximum 512 points (PIO Type), 768 points (only for SCON-CA Fieldbus Type)
(Note) Number of positions differs depending on the selection in PIO pattern and fieldbus operation mode.
Input Pulse Frequency Differential System (Line Driver System) : MAX. 2.5Mpps
Open Collector Type :
200Kpps max. (under condition AK-04 is used)
Pulse Train
Control
Mode
(Dedicated
for PIO
Specifications)
Command Pulse
Multiplying Factor
(Electrical Gear : A/B)
1/50 < A/B < 50/1
Setting Range of A and B (set to parameter) : 1 to 4096
Feedback Pulse
(Dedicated for PIO Specifications)
Differential System (Line Driver System) : MAX. 2.5Mpps
Open Collector Type :
500Kpps max. (under condition JM-08 is used)
LED Display
(mounted on Front Panel)
PWR (green) : Controller in normal condition,
SV (green) : Servo ON,
ALM (orange) : Alarm generated,
EMG (red) : Emergency Stop
PWR (green) : Controller in
normal condition / SV
(green) : Servo ON / ALM
(orange) : Alarm generated /
EMG (red) : Emergency
Stop / WRG (orange) :
Warning generated
Electromagnetic Brake Compulsory Release
Switch (mounted on Front Panel)
Switching NOM (standard)/BK RLS (compulsory release)
Insulation Resistance 500V DC 10MΩ or more
Insulation Strength 1,500V AC for 1 min. (Note) Withstand voltage of force control loadcell is 50V DC
Surrounding air temperature
0 to 40°C
Surrounding humidity
85%RH or less (non-condensing)
Surrounding environment
[Refer to Installation Environment]
Surrounding storage temperature
-20 to 70°C (non-condensing)
Surrounding storage humidity
85% or less (non-condensing)
Environment
Vibration Durability
XYZ Each direction 10 to 57Hz Pulsating amplitude 0.035mm (continuous) 0.075mm (intermittent)
57 to 150Hz 4.9m/s
2
(continuous) 9.8m/s
2
(intermittent)
Protection Class IP20 or equivalent
Mass Approx. 900g Approx. 1200g Approx. 560g
Cooling Method Natural air-cooling Forced Air Cooling Forced Air Cooling
External Dimensions 58W × 194H × 121D [mm] 72W × 194H × 121D [mm] 49W × 158H × 116D [mm]
*1 In-rush current will flow for approximately 20msec after the power is turned on (at 40°C).
Note that the value of in-rush current differs depending on the impedance of the power supply line.
*2 Leak current varies depending on the capacity of connected motor, cable length and the surrounding environment.
Measure the leak current at the point where a ground fault circuit interrupter is to be installed when leakage protection
is conducted.
A ground fault circuit interrupter needs to be selected carefully considering the purposes of prevention of fire and
protection of human.
Use the harmonic type (for inverter) for the ground fault circuit interrupter.
*3 It is not necessary to supply power to PIO when operating with using Fieldbus (EtherCAT®, EtherNet/IP,
PROFINET IO, DeviceNet, CC-Link, PROFIBUS-DP, CompoNet or MECHATROLINK), ROBONET, Gateway Unit or
SIO Converter without using PIO. In this case, set the parameter No. 74 (PIO Power Supply Monitor) to “1” (Invalid). It
will generate the error code No. 0CF (I/O 24V Power Supply Error) if the setting is not done.
Power Capacity and Heat Generation
Rated Power Capacity = Motor Power Capacity + Control Power Capacity
Peek Max. Power Capacity = Peek Max. Motor Power Capacity + Control Power Capacity
Actuator Motor Type
Motor Power
Capacity
[VA]
Peek Max.
Motor Power
Capacity [VA]
Control Power
Capacity
[VA]
Rated Power
Capacity
[VA]
Peek Max.
Power Capacity
[VA]
Heat
Generation
[W]
12 41 123 89 171 30
20 26 78 74 126 30
30D (Excluding RS) 46 138 94 186 31
30R (for RS) 138 414 186 462 33
60 138 414 186 462 33
60 (RCS3-CTZ5) 197 591
245 639 32
100 234 702 282 750 35
100S (LSA) 283 851 331 899 36
150 328 984 376 1032 37
200 421 1263 469 1311 38
200S
(LSA excluding LSA-N15H)
486 1458 534 1506 38
200S (LSA-N15H) 773 2319 821 2367 56
300S (LSA) 662 1986 710 2034 40
400 920 2760 968 2808 45
400 (RCS3-CT8) 1230 3690
1278 3738 47
600 1164 2328 1212 2376 56
750 3042 3090
750S
1521
4563
48
1569
4611
58
RS : Rotary Shaft LSA : Linear Actuator
Selection of Circuit Interrupter
3 times of the rated current flows to the controller during the acceleration/deceleration. Select an interrupter that does not trip
with this value of current. If a trip occurs, select an interrupter that possesses the rated current of one grade higher. [Refer to
the operation characteristics curves in the product catalog.]
Select an interrupter that does not trip with the in-rush current. [Refer to the operation characteristics curves in the product
catalog.]
Consider the current that enables to cutoff the current even when a short circuit current is flown for the rated cutoff current.
Rated Interrupting Current > Short Circuit Current = Primary Power Capacity / Power Voltage
Consider margin for the rated current on the circuit breaker.
Rated Current for Circuit Interrupter > (Rated Motor Power Capacity [VA] + Control Power Capacity [VA]) /
AC Input Voltage × Safety Margin (reference 1.2 to 1.4 times)
External Dimensions
Shown below are the dimensions for EtherCAT® type. The dimensions for EtherNet/IP and PROFINET IO should
also be the same.
SCON-CA
Less than 400W 400W or more
SCON-CAL/CGAL
49
122.6
4
158
146.5
(17)
(8.5)
(6)
(6)
φ4.5
22.5
4.5
For DIN Rail
Mounting Type
DIN Rail
For Screw-fixed Type
35.4 (Width of 35mm DIN Rail )
82.5 from DIN rail cente
r
* There is no DIN rail part on the type with screw attachment.
SCON-CA-20 I HA-NP-3-1-DN-**
<Series>
<Type>
C : Standard Type CA : High Performance Type
CAL : Small Type CGAL : Small Global Type
< Actuator Characteristics >
[Motor Type] * For SCON- CAL/CGAL, 200W or Less
12 : 12W 200 : 200W
20 : 20W 200S : 200W (LSA)
30D : 30W (Excluding RS) 300S : 300W (LSA)
30R : 30W (for RS) 400 : 400W
60 : 60W 600 : 600W
100 : 100W 750 : 750W
100S : 100W (LSA) 750S : Equipped with loadcell
150 : 150W RCS2-RA
<Encoder Type>
I : Incremental A : Absolute G : Spurious Absolute
(Note 1)
<Option>
No Indication : Standard Type I : Index Absolute Type (DD)
(Note 1)
HA : High Acceleration/Deceleration Type
M : Multi-Rotation Absolute Type (DD)
(Note 1)
<Identification for IAI use only>
* There is no identification in some cases.
< Type of Installation
(dedicated for SCON-CAL/CGAL)>
Not Specified : Screw Attachment Type
DN : DIN Rail Mounting Type
<Power-supply Voltage>
1 : Single-Phase 100V AC
2 : Single-Phase 200V AC
<I/O Cable Length>
0 : Equipped with no cable 2 : 2m
3 : 3m (Standard) 5 : 5m
In Absolute Battery Attachment
(Absolute Encoder Type)
In Absolute Battery Attachment
(Absolute Encoder Type)
Side View (Common)
Model
Serial number
SCON-CA-60A-EC-2-1
MODEL
SERIAL No.
800056144 L11
MADE IN JAPAN
Warning : Operation of this equipment requires detailed installation and operation instructions which are
provided on the DVD Manual included in the box this device was packaged in. It should be retained
with this device at all times.
A hardcopy of the Manual can be requested by contacting your nearest IAI Sales Office listed at
the back cove
r
of the Instruction Manual or on the First Ste
p
Guide.
<I/O Type>
NP : NPN Specification (Sink Type) (Standard) ML : MECHATROLINK
ⅠⅡ
Connection 1,2 Type
PN : PNP Specification (Source Type) ML3 : MECHATROLINK
Connection 3 (Motion) Type
(Note 1)
DV : DeviceNet Connection Type EC : EtherCAT Connection Type
CC : CC-Link Connection Type EP : EtherNet/IP Connection Type
PR : PROFIBUS-DP Connection Type PRT : PROFINET IO Connection Type
CN : CompoNet Connection Type
(Note 1) Specified only for SCON-CA